Whirlpool GCGM2991LQ0 User Manual

Page of 24
6
CHECKING YOUR VENT
Your dryer must be properly installed and vented to achieve 
maximum drying efficiency and shorten drying times. Use the 
minimum recommended installation clearances (found in your 
Installation Instructions) to avoid blocking the flow of combustion 
and ventilation air. Refer to your Installation Instructions for more 
information.
If the dryer is not properly installed and vented, it will not be 
covered under the warranty.
NOTE: 
Service calls caused by improper venting will be paid for 
by the customer, whether it was a paid installation or self-
installed. 
1.
Do not use plastic vent or metal foil vent. Use 4 in. (10.2 cm) 
metal or flexible metal vent. Do not kink or crush flexible 
metal vent. It must be completely extended to allow adequate 
exhaust air to flow. Check vent after installation. Refer to your 
Installation Instructions for proper length requirements of vent.
2.
Use a 4 in. (10.2 cm) exhaust hood. Smaller hoods increase 
drying times.
3.
The exhaust vent can be routed up, down, left, right, or 
straight out the back of the dryer. Space requirements are 
listed in your Installation Instructions.
4.
Use the straightest path possible when routing the exhaust 
vent. Use the fewest number of elbows and turns. Allow room 
when using elbows or making turns. Bend vent gradually to 
avoid kinking.
5.
Use duct tape to seal all joints. Do not use screws to secure 
vent. Lint may catch on screws.
6.
Clean exhaust vent periodically, depending on use, but at 
least every 2 years, or when installing your dryer in a new 
location. 
Disconnect vent from the dryer and clean one section at a 
time until you reach the exhaust hood.
To clean out lint, use the hose attachment on your 
vacuum, or a pole or wire with a feather duster or rag 
attached.
Be sure the flapper on the outside end of vent moves 
freely.
When cleaning is complete, be sure to follow the 
Installation Instructions supplied with your dryer for final 
product check.
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in 
death or fire.
      4"
(10.2 cm)
     4"
(10.2 cm)
      4"
(10.2 cm)