Startup Procedure for Inband Management
With inband management, the BitStorm 4800 Express is managed using the 
uplink port. 
To start up the BitStorm 4800 Express using inband management:
To avoid losing your connection when the IP address is changed, access 
the CLI using the CONSOLE port. 
Assign an IP address, netmask, and next-hop router using the configure 
management command. For example:
PDYN# configure management inband address 137.90.127.3 
255.255.255.0
PDYN# configure management default-gateway 137.90.127.1
Do not configure inband and out-of-band management on the same 
subnet.
Startup Procedure for Out-of-Band Management
In out-of-band management, you manage the unit through Port 1.
To start up the BitStorm 4800 Express using out-of-band management:
To avoid losing your connection when the IP address is changed, access 
the CLI using the CONSOLE port.
Assign an IP address, netmask, and next-hop router using the configure 
management command. For example:
PDYN# configure management out-of-band address 137.90.80.3 
255.255.255.0
PDYN# configure management default-gateway 137.90.80.1
You can now access the web interface by typing into the Location field of 
your web browser the IP address assigned to the Port 1. See 
Do not configure inband and out-of-band management on the same 
subnet.
Configure routers as necessary to route data from the NOC to the 
BitStorm 4800 Express.