Siemens Network Hardware D410 User Manual

Page of 150
 
Commissioning (software) 
 
4.2 Configuring the system in offline mode 
D410 
Commissioning Manual, 08/2008 Edition 
63
 
4.2.2 
Accessing the drive wizard 
Integrated drive 
SIMOTION D410 features an integrated SINAMICS S120 drive (control unit) which is 
automatically included when you insert the SIMOTION D410 in the Project Navigator. The 
integrated drive must be operated in equidistant, isochronous mode using PROFIdrive-
compliant message frame types.  
The integrated drive and its associated modules (SINAMICS S120 motor modules, for 
example) are configured using the Drive Wizard of the integrated STARTER in SIMOTION 
SCOUT. 
 
 
Note 
Observe all necessary safety information and wiring rules in the corresponding current 
SINAMICS S120 documentation. 
 
Procedure 
Select the "SINAMICS_Integrated" > "Configure drive unit" drive element in the Project 
Navigator to open the Drive Wizard.  
You can configure the following components: 
●  Power unit (e.g. SINAMICS S120 PM340 power module) 
●  Motor 
●  Encoder