Siemens Network Hardware SM2 monitoring system User Manual

Page of 500
U3585-J-Z125-8-76
133
Statements for SM2 administrators
SET-TASK-PARAMETER
TSN =
TSN = *NOT-SPECIFIED
No tasks are selected using the TSN.
TSN = list-poss(64): <alphanum-name 1..4>
Specifies the TSNs of the tasks to be monitored. A task with the specified TSN is,
however, only monitored if it already existed when the task monitoring program was
started.
USER-ID =
USER-ID = *NOT-SPECIFIED
No tasks are selected using the user ID.
USER-ID = list-poss(32): <alphanum-name 1..8>
Specifies the user ID of the tasks to be monitored. An asterisk (*) is also permitted as
the last character in a wildcard specification. All tasks of the specified user ID which
existed at the start of the task monitoring program or which were created during the
monitoring program run are monitored. The user IDs must be specified without the “$”
sign.
JOB-NAME =
JOB-NAME = *NOT-SPECIFIED
No tasks are selected via their job names.
JOB-NAME = list-poss(32): <alphanum-name 1..8>
Specifies the job name of the task to be monitored. An asterisk (*) is also permitted as
the last character in a wildcard specification. All tasks with the job name specified at
selection time using the START-MEASUREMENT-PROGRAM or LOGON command
are monitored.
JOB-CLASS =
JOB-CLASS = *NOT-SPECIFIED
No tasks are selected via their job class.
JOB-CLASS = list-poss(32): <alphanum-name 1..8>
Specifies the job class of the tasks to be monitored. An asterisk (*) is also permitted as
the last character in a wildcard specification. All tasks with the job name specified at
selection time using the START-MEASUREMENT-PROGRAM or LOGON command
are monitored.