U3585-J-Z125-8-76
DAB CACHE report
SM2 reports
Monitoring information
Each line in this report contains data on the different subareas or files served by the cache
with the specified CACHE-ID.
The individual columns contain the following data:
VSN / FILE
VSN of the volume containing the subarea or, if DAB supports a file,
the name of the file containing the subarea. If there is more than one
subarea on the same volume or in the same file, these subareas are
listed in successive lines. The relevant VSN or file name can be
found only in the first line of this list. If the file name is longer than
21 characters, it is truncated on the right.
FIRST-HP,LAST-HP
First and last physical block numbers of the subarea, if a volume is
listed in column 1.
First and last logical block numbers of the subarea, if a file name is
listed in column 1.
S
Any subarea which was not served during the last monitoring cycle
is marked with an asterisk (*) in this column (S = served). No data
is output for this subarea.
The columns READ, RD-HIT, WRITE, WR-HIT and OVER have the same meaning as in the
DAB report. However, the information they contain refers to individual subareas or files and
not to the DAB cache as a whole.
DD017ZE03 SM2 DAB CACHE           CYCLE:   60 S               99-03-24  11:11:02
 ID: BUFFER#001           (DAB13V23)  MOD: R      MED:GS SIZE(FIX):   12.0 MB
 |    VSN / FILE       |FIRST-HP,LAST-HP |S| READ  |RD-HIT| WRITE |WR-HIT|OVER |
 |                     |                 | | (1/S) | (%)  | (1/S) | (%)  |(1/S)|
 +---------------------+-----------------+-+-------+------+-------+------+-----+
 |*SUMMARY             |       1-       1| | 117.2 | 99.4 | 113.7 |  0.0 | 0.0 |
 +---------------------+-----------------+-+-------+------+-------+------+-----+