MODIFY-COSMOS-PARAMETER
LOCK-ID = *UNCHANGED
The currently specified lock IDs are not changed.
LOCK-ID = *ANY
The recording of LOCK events is independent of their lock ID.
LOCK-ID = list-poss(4): <alphanum-name 1..2>
Only those LOCK events with the specified lock IDs are recorded.
TLT-DESCRIPTOR =
Controls the recording of TLT on the basis of their TLT descriptor (TLT = Task Location
Table).
TLT-DESCRIPTOR = *UNCHANGED
The currently specified values for the TLT descriptor are not changed.
TLT-DESCRIPTOR = *ANY
The recording of TLT events is independent of their TLT descriptor.
TLT-DESCRIPTOR = list-poss(8): <alphanum-name 1..3>
Only those TLT events with the specified TLT descriptors are recorded.
TSKI-SWITCH =
Controls the recording of TSKI events on the basis of their TIC (Task in Control).
TSKI-SWITCH = *UNCHANGED
The currently specified value for TSKI-SWITCH is not changed.
TSKI-SWITCH = *ANY
The recording of TSKI events is independent of their TIC.
TSKI-SWITCH = *TASK
Only the first TSKI event of a TIC is recorded.
TSVC-SVC-NUMBER =
Controls the recording of TSVC events on the basis of their SVC numbers.
TSVC-SVC-NUMBER = *UNCHANGED
The currently specified SVC numbers are not changed.
TSVC-SVC-NUMBER = *ANY
The recording of TSVC events is independent of their SVC number.
TSVC-SVC-NUMBER = list-poss(8): <integer 1..255>
The TSVC events are recorded for the specified SVC numbers.
UNLOAD =
Specifies the time at which the COSMOS subsystem is to be unloaded.
UNLOAD = *UNCHANGED