Electrical System
Fusible Links
The wiring harness for the Workman includes three (3)
fusible links for circuit protection (Fig. 36).
Two (2) fusible links attach to the same main contactor
post as the main fuse. One of these fusible links (FL2)
is used for the switched power circuit. The other fusible
link (FL1) protects the charger circuit.
The third fusible link (FL3) is attached to the controller
B+ terminal. This link provides protection for the charge
indicator/hour meter gauge.
If any of these fusible links should fail, the affected circuit
will not function. See Chapter 6 -- Electrical Diagrams for
schematic and wire harness information.
1. Main contactor
2. Main fuse contactor post
3. Switched contactor post
4. Fusible links FL1 & FL2
5. Fusible link FL3