John Deere Products & Services Portable Generator DCA70SSJU4i User Manual

Page of 120
dca70SSJU4i 60 hz generator• operation manual — rev. #2 (04/09/14) — page 39
GeNeratOr shUt-DOWN prOCeDUres
normal shutdoWn procedure
To shutdown the generator, use the following procedure:
1.  Place both the 
main, gFci and load circuit breakers 
as shown in Figure 54 to the 
OFF position.
Figure 54. Main, Aux. and GFCI  
Circuit Breakers (OFF)
2.  Let the engine cool by running it at low speed for 3-5 
minutes with no load applied.
3.  Place the 
auto off/reset manual switch (Figure 55) 
in the 
oFF/reset position.
Figure 55. 
auto off/reset manual
 Switch 
 (Off/Reset)
4.  Verify that all status LEDs on the ECU control panel 
are 
OFF (not lit). 
5.  Remove all loads from the generator.
  Warning
never stop the engine suddenly except in an 
emergency. 
6.  Place the 70 amp circuit breaker switch (Figure 56) on 
the 600 VAC control box enclosure to the OFF position.
Figure 56. Circuit Breaker OFF (600 VAC)
7.  Inspect entire generator for any damage or loosening of 
components that may have occurred during operation.
emergencY shutdoWn procedure
1.  Place the 
mpec control switch ( in the oFF/reset 
position.
automatic shut-doWn sYstem
This unit is equipped with safety devices to automatically 
stop the engine in the event of low oil pressure, approximately 
14 psi (97 kPa), or high water temperature, approximately 
230° F (110° C), overspeed approximately +15%. The alarm 
lamps on the ECU illuminate to signify the reason for the 
shutdown.
OFF
NOTICE
Before inspecting generator, check that the Auto/
Manual switch is in the 
oFF/reset position, and place 
all circuit breakers in the
 OFF position. Allow sufficient 
time for adequate cooling. When ready to restart, 
complete all steps in the Generator Startup Procedure 
section of this manual.