8
Power LED 
 
Those LED light up when Power is available on the 
connector next to the LED 
Incoming data LED 
Those LED flashes, when the unit receives 
incoming data from connected units on the 
connector next to the LED.
System design 
There are  no settings to be done on the RP 6004 
Repeater.  
However it is important to observe, that the unit is 
only repeating one of the chains on the CU 6010 
Central Unit.  
And as so, the specification, which applies to each 
of the chain outputs on the CU 6010 Central Units 
does also apply to all the repeated outputs in total. 
So when designing a system to incorporate RP 6004 
Repeaters, bare in mind, that as the RP 6004 
Repeater is repeating only one of the four outputs A  
(A1 or A2) or B (B1 or B2) the max. number of 
languages configured on the four outputs (1, 2, 3 
and 4)  is totally max. 16.  
If more languages are required, Interpreter sets for 
those languages have to be connected either to an 
other RP 6004 Repeater, which is connected to the 
other of the two chains (A or B) on the CU 6010, or 
directly to the other of the two chains (A or B) on a 
CU 6010. 
  
‘Repeated chain’ connector 
 
When connecting the RP 6004 Repeaters to the CU 
6010 the first RP 6004 is connected to the ‘Loop 
through’ connector. The next RP 6004 Repeaters 
can be connected to either the other ‘Loop through’ 
connector or to one of the ‘Repeated out’ 
connectors. If using the ‘Repeated’ outputs 
maximum two more RP 6004 Repeaters can be 
connected extending the maximum cable length in 
one chain up to 650 m. The above schematic is 
showing the connection using the ‘‘Repeated out’ 
connectors.