Home Automation OmniPro II User Manual

Page of 100
Unit Numbers 
 
OmniPro II systems have 511 total Unit Numbers.  They consist of HLC, UPB, CentraLite, RadioRA, ALC, Compose, and X-10 
module unit numbers, hardwire voltage output unit numbers, and internal flag unit numbers as follows: 
 
 
OmniPro II Unit Numbers 
Module / Output Unit Numbers 
 
1 - 16 
HLC Room 1 and 2, UPB Unit ID 1-16, CentraLite loads 1-16, RadioRA Lighting Zones or 
Master Controls 1-16, and X-10 modules 1 – 16 (House Code X) 
 
17 - 32 
HLC Room 3 and 4, UPB Unit ID 17-32, CentraLite loads 17-32, RadioRA Lighting Zones 
and Master Controls 17-32, or X-10 modules 1 – 16 (House Code X+1) 
(1 - 31) 
ALC addresses 1-31, Module 1 - Branch 1 * 
33 - 48 
HLC Room 5 and 6, UPB Unit ID 33-48, CentraLite loads 33-48, RadioRA Lighting Zones 
and Master Controls 33-48, or X-10 modules 1 – 16 (House Code X+2) 
49 - 64 
HLC Room 7 and 8, UPB Unit ID 49-64, CentraLite loads 49-64, RadioRA Lighting Zones 
and Master Controls 49-64, or X-10 modules 1 – 16 (House Code X+3) 
(33 - 63) 
ALC addresses 1-31, Module 1 - Branch 2 * 
65 - 80 
HLC Room 9 and 10, UPB Unit ID 65-80, CentraLite loads 65-80, or X-10 modules 
1 – 16 (House Code X+4) 
81 - 96 
HLC Room 11 and 12, UPB Unit ID 81-96, CentraLite loads 81-96, or X-10 modules 
1 – 16 (House Code X+5) 
(65 - 95) 
ALC addresses 1-31, Module 1 - Branch 3 * 
97 - 112 
HLC Room 13 and 14, UPB Unit ID 97-112, CentraLite loads 97-112, or X-10 modules 
1 – 16 (House Code X+6) 
113 - 128 
HLC Room 15 and 16, UPB Unit ID 113-128, CentraLite loads 113-128, or X-10 modules 
1 – 16 (House Code X+7) 
(97 - 127) 
ALC addresses 1-31, Module 1 - Branch 4 * 
129 - 144 
HLC Room 17 and 18, UPB Unit ID 129-144, CentraLite loads 129-144, or X-10 modules 
1 – 16 (House Code X+8) 
145 - 160 
HLC Room 19 and 20, UPB Unit ID 145-160, CentraLite loads 145-160, or X-10 modules 
1 – 16 (House Code X+9) 
(129 - 159) 
ALC addresses 1-31, Module 2 - Branch 1 * 
161 - 176 
HLC Room 21 and 22, UPB Unit ID 161-176, CentraLite loads 161-176, or X-10 modules 
1 – 16 (House Code X+10) 
177 - 192 
HLC Room 23 and 24, UPB Unit ID 177-192, CentraLite loads 177-192, or X-10 modules 
1 – 16 (House Code X+11) 
(161 - 191) 
ALC addresses 1-31, Module 2 - Branch 2 * 
193 - 208 
HLC Room 25 and 26, UPB Unit ID 193-208, or X-10 modules 1 – 16 (House Code X+12) 
209 - 224 
HLC Room 27 and 28, UPB Unit ID 209-224, or X-10 modules 1 – 16 (House Code X+13) 
(191 - 223) 
ALC addresses 1-31, Module 2 - Branch 3 * 
225 - 240 
HLC Room 29 and 30, UPB Unit ID 225-240, or X-10 modules 1 – 16 (House Code X+14) 
241 - 256 
HLC Room 31, UPB Unit ID 241-250, or X-10 modules 1 – 16 (House Code X+15) 
(225 - 255) 
ALC addresses 1-31, Module 2 - Branch 3 * 
257 – 272 
Outputs 1-16, 1st Expansion Enclosure * 
273 – 288 
Outputs 1-16, 2nd Expansion Enclosure * 
289 – 304 
Outputs 1-16, 3rd Expansion Enclosure * 
305 – 320 
Outputs 1-16, 4th Expansion Enclosure * 
321 - 336 
Outputs 1-16, 5th Expansion Enclosure * 
337 – 352 
Outputs 1-16, 6th Expansion Enclosure * 
353 - 368 
Outputs 1-16, 7th Expansion Enclosure * 
369 - 384 
Outputs 1-16, 8th Expansion Enclosure * 
385 - 392 
Voltage Outputs (1-8), Fully Configurable 
393 – 511 
Internal Flags 
 
 
 
“X”  Represents the House Code setting on the OmniPro II Controller 
 “*” 
 
Internal 
Flags 
 
Page 20