Справочник Пользователя для Home Automation OmniPro II

Скачать
Страница из 100
Unit Numbers 
 
OmniPro II systems have 511 total Unit Numbers.  They consist of HLC, UPB, CentraLite, RadioRA, ALC, Compose, and X-10 
module unit numbers, hardwire voltage output unit numbers, and internal flag unit numbers as follows: 
 
 
OmniPro II Unit Numbers 
Module / Output Unit Numbers 
 
1 - 16 
HLC Room 1 and 2, UPB Unit ID 1-16, CentraLite loads 1-16, RadioRA Lighting Zones or 
Master Controls 1-16, and X-10 modules 1 – 16 (House Code X) 
 
17 - 32 
HLC Room 3 and 4, UPB Unit ID 17-32, CentraLite loads 17-32, RadioRA Lighting Zones 
and Master Controls 17-32, or X-10 modules 1 – 16 (House Code X+1) 
(1 - 31) 
ALC addresses 1-31, Module 1 - Branch 1 * 
33 - 48 
HLC Room 5 and 6, UPB Unit ID 33-48, CentraLite loads 33-48, RadioRA Lighting Zones 
and Master Controls 33-48, or X-10 modules 1 – 16 (House Code X+2) 
49 - 64 
HLC Room 7 and 8, UPB Unit ID 49-64, CentraLite loads 49-64, RadioRA Lighting Zones 
and Master Controls 49-64, or X-10 modules 1 – 16 (House Code X+3) 
(33 - 63) 
ALC addresses 1-31, Module 1 - Branch 2 * 
65 - 80 
HLC Room 9 and 10, UPB Unit ID 65-80, CentraLite loads 65-80, or X-10 modules 
1 – 16 (House Code X+4) 
81 - 96 
HLC Room 11 and 12, UPB Unit ID 81-96, CentraLite loads 81-96, or X-10 modules 
1 – 16 (House Code X+5) 
(65 - 95) 
ALC addresses 1-31, Module 1 - Branch 3 * 
97 - 112 
HLC Room 13 and 14, UPB Unit ID 97-112, CentraLite loads 97-112, or X-10 modules 
1 – 16 (House Code X+6) 
113 - 128 
HLC Room 15 and 16, UPB Unit ID 113-128, CentraLite loads 113-128, or X-10 modules 
1 – 16 (House Code X+7) 
(97 - 127) 
ALC addresses 1-31, Module 1 - Branch 4 * 
129 - 144 
HLC Room 17 and 18, UPB Unit ID 129-144, CentraLite loads 129-144, or X-10 modules 
1 – 16 (House Code X+8) 
145 - 160 
HLC Room 19 and 20, UPB Unit ID 145-160, CentraLite loads 145-160, or X-10 modules 
1 – 16 (House Code X+9) 
(129 - 159) 
ALC addresses 1-31, Module 2 - Branch 1 * 
161 - 176 
HLC Room 21 and 22, UPB Unit ID 161-176, CentraLite loads 161-176, or X-10 modules 
1 – 16 (House Code X+10) 
177 - 192 
HLC Room 23 and 24, UPB Unit ID 177-192, CentraLite loads 177-192, or X-10 modules 
1 – 16 (House Code X+11) 
(161 - 191) 
ALC addresses 1-31, Module 2 - Branch 2 * 
193 - 208 
HLC Room 25 and 26, UPB Unit ID 193-208, or X-10 modules 1 – 16 (House Code X+12) 
209 - 224 
HLC Room 27 and 28, UPB Unit ID 209-224, or X-10 modules 1 – 16 (House Code X+13) 
(191 - 223) 
ALC addresses 1-31, Module 2 - Branch 3 * 
225 - 240 
HLC Room 29 and 30, UPB Unit ID 225-240, or X-10 modules 1 – 16 (House Code X+14) 
241 - 256 
HLC Room 31, UPB Unit ID 241-250, or X-10 modules 1 – 16 (House Code X+15) 
(225 - 255) 
ALC addresses 1-31, Module 2 - Branch 3 * 
257 – 272 
Outputs 1-16, 1st Expansion Enclosure * 
273 – 288 
Outputs 1-16, 2nd Expansion Enclosure * 
289 – 304 
Outputs 1-16, 3rd Expansion Enclosure * 
305 – 320 
Outputs 1-16, 4th Expansion Enclosure * 
321 - 336 
Outputs 1-16, 5th Expansion Enclosure * 
337 – 352 
Outputs 1-16, 6th Expansion Enclosure * 
353 - 368 
Outputs 1-16, 7th Expansion Enclosure * 
369 - 384 
Outputs 1-16, 8th Expansion Enclosure * 
385 - 392 
Voltage Outputs (1-8), Fully Configurable 
393 – 511 
Internal Flags 
 
 
 
“X”  Represents the House Code setting on the OmniPro II Controller 
 “*” 
 
Internal 
Flags 
 
Page 20