Honeywell Work Light DR4300 User Manual
DR4300 Circular Chart Recorder
158
DR4300 Circular Chart Recorder Product Manual
12/03
6.2 Replacing the Chart
Procedure
Table 6-1 Procedure for Replacing the Chart
Step Action
1
Turn off the power to the recorder, then open the door.
2
Pull up on the pen lifter to raise the pen(s) from the chart plate.
3
Lift the chart from the hub, and slide it from under the pen(s) to remove it from the chart plate.
4
Slip the new chart under the pen lifter, pens and time index; and press the chart into place over
the chart hub.
the chart hub.
5
Turn the chart until the desired time line on the chart is aligned with the time index on the chart
plate and pen 1 before closing the locking clip on the hub. Push down on the lifter to return the
pen(s) to the chart.
plate and pen 1 before closing the locking clip on the hub. Push down on the lifter to return the
pen(s) to the chart.
CAUTION: Do not try to rotate the hub
6
Close the door and apply power.
24214
Pen arm
Clip
Ink
cartridge
cartridge
Notch for
pen tip
pen tip
Open
clip
clip
Pen
tip
tip
Large chart
hub
hub
Time index
Pen lifter
Figure 6-1 Replacing the Chart and Ink Cartridge