Hitachi GR2000 User Manual

Page of 410
Component Details
GR2K-GA-1002
3-21
Rev. 6.03
3.5.3
NE1G-1S, NE1G-1SA, NE1G-1L, NE1G-1LA, NE1G-1LHA, NE1G-1LHA8,
NE1G-1LB, NE1G-1SB and NE1G-1LHBA
The NE1G-1S, NE1G-1SA, NE1G-1L, NE1G-1LA, NE1G-1LHA, NE1G-1LHA8,
NE1G-1LB, NE1G-1SB and NE1G-1LHBA physically appear as Figure 3-24.
These NIFs each have one port for connection with a pair of SC 2-core optical fiber
connectors (transmit and receive). Table 3-20 shows the connector specifications.
Figure 3-24 NE1G-1S, NE1G-1SA, NE1G-1L, NE1G-1LA, NE1G-1LHA, NE1G-1LHA8,
NE1G-1SB, NE1G-1LB and NE1G-1LHBA Front Panel View
Switch and LED indication
Table 3-19 NE1G-1S, NE1G-1SA, NE1G-1L, NE1G-1LA, NE1G-1LHA, NE1G-1LHA8,
NE1G-1LB, NE1G-1SB and NE1G-1LHBA switch and function of LED
indications
Name
Name of switch
and LED
Status
Content
STATUS
LED: Green/
Yellow/ Red
Shows the operating
condition of RM.
Green: Operable operation
Yellow: Blocking and the board replaceable state.
Green blinking: Under preparation (Program being
loaded.)
Red: Fault
Extinguished: Operation not possible (Including the
device power supply being turned off)
LINE
LED: Green
Green: Ring pulse being established
ACT
LED: Green
Shows the operating
condition of each line.
Green: Line operation possible state (line open state)
LINE ERR
LED: Yellow
Yellow: Line section II/W fault detection.
R
LED: Green
Frame signal being received.
T
LED: Green
Frame signal being transmitted.
SIG-DT
LED: Green
Signal detect operation detected.
R
T
SIG-DT
LINK
ACT
LINE ERR
ST
AT
U
S
NE
1
G
-1
**
LINE 0
T
R
1000BASE-SX or
1000BASE-LX or
1000BASE-LH
Mark ** indicates 1S, 1SA, 1SB, 1L,
1LA, 1LB, 1LHA, 1LHAB, and 1LHBA.