Certifications 
 
 
North American Certifications 
CSA Class I, Div 1, Group B, C, D; T4 
 
European Directive Compliance (CE Mark) 
 
EEx d, IIB+H
2
; T4  
97/23/EC Pressure Equipment Directive (PED)  
94/9/EC Potentially Explosive Atmospheres (ATEX)    02ATEX6051X 
98/37/EC Machinery Directive  
89/336/EEC Electromagnetic Compatibility Directive (EMC) 
 
 
Materials 
 
 
Actuator Housing 
6061-T6 Anodized Aluminum 
 
Valve Housing 
6061-T6 Anodized Aluminum 
316 Stainless Steel (Optional) 
 
Conduit Union 
Zinc Plated Steel 
 
Seals 
Viton and Teflon 
 
Connectors Aluminum 
 
 
Dimensions 
9.7 in x7.7 in x 25.4 in 
 
 
Weight 
100 lbs. Max (Aluminum Valve Housing, 3-piece) 
85 lbs. Max (Aluminum Valve Housing, 1-piece) 
190 lbs. Max (Stainless Steel Valve Housing, 3 piece) 
 
 
1.3  Mechanical Installation 
This section describes proper HFG2.0 installation. Ensure compliance 
with the factory recommendations. 
 
Typical Fuel System 
 
The HFG2.0 installs as part of a gas fuel system as shown in Figure 1-1. 
In this arrangement, the HFG2.0 is located downstream from two 
normally closed gas shut-off valves. 
An alternate arrangement is shown in Figure 1-2. In this installation, the 
HFG2.0 is located between two normally closed gas shut-off valves. 
 
Fuel Filtering 
For efficient valve operation, filter the fuel through a 40-micron absolute 
filter before it reaches the valve. This extends the time between routine 
maintenance. Locate the fuel filter as close as possible to the valve 
INLET.