Hamilton Sundstrand Company Gas Fuel Metering Valve HFG2.0 User Manual

Page of 70
 
6 HFG2.0 
USER 
GUIDE
 
The HFG2.0 includes four (4) 0.50-24 UNC-2B mounting holes with 
stainless steel heli-coil inserts for securing the valve body. The mounting 
holes on the standard version of the HFG2.0 are located on the opposite 
side from the electrical connectors. The mounting holes on the reversed 
version of the HFG2.0 are located on the same side as the electrical 
connectors (see Figure 1-5). 
Figure 1-6 shows mounting provisions for the 3-piece housing version of 
the HFG2.0.  Figure 1-7 and Figure 1-8 show mounting provisions for the 
1-piece housing version of the HFG2.0. 
Note: Provide adequate clearance to the OUTLET port to facilitate 
cleaning. 
Lifting Considerations 
The aluminum body HFG2.0 weighs approximately 100 lbs. The stainless 
steel body HFG2.0 weighs approximately 190 lbs. PECC recommends 
using the 0.375-inch diameter clevis to lift the valve, in conjunction with 
the appropriate lifting equipment. 
Note: The clevis exceeds the Factor of Safety (FOS) requirement 
of 3, based on component yield strength, per ASME B30.20-
1999. 
 
WARNING 
Lifting Hazard – Do not attempt to hand-lift the actuator. Use 
appropriate lifting equipment. 
Connecting the Clevis 
The clevis can be used to secure the actuator end of the HFG2.0. A high-
strength shoulder bolt (0.375” diameter) is recommended to fasten the 
clevis to a user-provided mount bracket. 
The clevis can be rotated to any orientation to support installation. Loosen 
the four retaining screws and rotate to the desired angle. The screw 
pattern can be indexed 
± 45 degrees to provide additional adjustment. 
When adjustments are complete, torque the four retaining screws to 
117-138 in-lbs.