Hamilton Sundstrand Company Gas Fuel Metering Valve HFG2.0 User Manual

Page of 70
 
 
 
Fault Type 
Low 
Alarm 
High 
Alarm 
Fault 
Enable 
Persist 
Time 
Auto 
Reset 
Output 
Driver Overcurrent 
N/A 
1000 lbf 
Yes 
10 Sec 
Yes 
Yes 
Tracking Error 
N/A 
3.33 % 
Yes 
10 Sec 
Yes 
Yes 
Position Demand 
3.5 mA 
20.5 mA 
No 
1 Sec 
No 
No 
RDC 
Failure  N/A  N/A Yes N/A  No 
Yes 
+14 Volts 
12.0 Volts 
16.0 Volts 
Yes 
7.5 Sec 
Yes 
Yes 
–14 Volts 
–16.0 Volts 
–12.0 Volts 
Yes 7.5 
Sec Yes Yes 
Input Voltage 
75.0 Volts 
180.0 Volts 
Yes 
7.5 Sec 
Yes 
Yes 
EEPROM 
Checksum 
N/A  N/A Yes N/A  No 
Yes 
Motor High Temp 
N/A 
130° C 
No 
10 Sec 
No 
No 
Electronics High Temp 
N/A 
110° C 
Yes 
10 Sec 
Yes 
Yes 
+5 Volts 
4.5 Volts 
5.5 Volts 
Yes 
7.5 Sec 
Yes 
Yes 
Watchdog 
Expired N/A  N/A Yes N/A  No 
Yes 
EEPROM 
Write  N/A  N/A Yes N/A  No 
Yes 
Table 3-1.  Default Configuration For FAULT Alarm  
 
 
Fault Type 
Low 
Alarm 
High 
Alarm 
Fault 
Enable 
Persist 
Time 
Shut- 
Down 
Output 
Driver Overcurrent 
N/A 
1000 lbf 
No 
10 Sec 
No 
No 
Tracking Error 
N/A 
3.33 % 
No 
10 Sec 
No 
No 
Position Demand 
2 mA 
22 mA 
No 
1 Sec 
No 
No 
RDC 
Failure  N/A  N/A No N/A No 
No 
+14 Volts 
12.0 Volts 
16.0 Volts No  7.5 
Sec  No  No 
–14 Volts 
–16.0 Volts 
–12.0 Volts No  7.5 
Sec  No  No 
Input Voltage 
75.0 Volts 
180.0 Volts 
No 
7.5 Sec 
No 
No 
EEPROM Checksum 
N/A 
N/A 
No 
7.5 Sec 
No 
No 
Motor High Temp 
N/A 
135° C 
Yes 
10 Sec 
Yes 
Yes 
Electronics High Temp 
N/A 
110° C 
No 
10 Sec 
No 
No 
+5 Volts 
4.0 Volts 
6.0 Volts 
No 
7.5 Sec 
No 
No 
Watchdog 
Expired N/A  N/A No N/A No 
No 
EEPROM 
Write N/A  N/A No N/A No 
No 
Table 3-2.  Default Configuration For OVERTEMP Alarm  
 
 
 
 