Hampton Direct H200 User Manual

Page of 32
Hampton H200 Cast Freestanding Woodstove
9
MINIMUM ALCOVE CLEARANCE TO
COMBUSTIBLE MATERIALS
This Hampton Freestanding model has been alcove approved and must be installed 
with a listed double wall connector to the ceiling level. 
Note:  Minimum alcove ceiling height (from fi nished fl oor) - 60" (1525 mm)
 
 
Maximum depth of alcove - 48" (1220 mm)
INSTALLATION 
                           
 
          From                                  From Flue                            Min.                    Min.Hearth 
            Unit (with Heat Shield) 
         Unit 
                              Center-line                             Width               to Rear Wall 
 
                                              G                        H 
              I                      J                         K                         L
   H200                                                            15" (381 mm)       13" (330 mm)   27" (686 mm)    15-1/8" (384 mm)   54" (1372 mm)   50" (1270 mm)
 
 
 
 
                      
 
                             
ADDITIONAL CLEARANCES
FOR BACKWALL EXIT
                           
 
          From
            Unit (with Heat Shield) 
         Unit 
 
                                              A                       B 
            
   H200                      
                                      9" (228 mm)        15" (381 mm)
Note:  Floor Protection must extend 2" (50mm) 
to each side of the elbow.
Minimum Clearance to Combustibles 
Minimum Clearance to Non-Combustibles 
                           
 
          From   
                        
            Unit (with Heat Shield) 
         Unit 
 
             
 
                                              A                       B 
             
   H200                                                            min. 0" (0 mm)       15" (381 mm) 
          
 
                               max. 9" (228 mm)
 
 
 
 
Min. Mantel Height (from fi nished fl oor): 48" 
(1219 
mm)
Max. Mantel Depth:     12" 
(305 
mm)