Hampton Direct H300 User Manual
Hampton H300 Cast Freestanding Woodstove
9
MINIMUM ALCOVE CLEARANCE TO
COMBUSTIBLE MATERIALS
This Hampton Freestanding model has been alcove approved and must be installed
with a listed double wall connector to the ceiling level.
with a listed double wall connector to the ceiling level.
Note: Minimum alcove ceiling height - 60" (1525 mm)
Maximum depth of alcove - 48" (1220 mm)
INSTALLATION
From From Flue Min. Min.Hearth
Unit (with Heat Shield)
Unit
Center-line Width to Rear Wall
G H
I J K L
H300 15" (381 mm) 13" (330 mm) 28" (711 mm) 13" (330 mm) 57" (1448 mm) 51-1/4"
without side load door
(1301 mm)
ADDITIONAL CLEARANCES
FOR BACKWALL EXIT
From
Unit (with Heat Shield)
Unit
A B
H300 9" (228 mm) 15" (381 mm)
Note: Floor Protection must extend 2" (50mm)
to each side of the elbow.
Note: If side load door is used, fl oor protection
must extend at least 18" (457mm) from
the side of the unit.
the side of the unit.
Minimum Clearance to Combustibles
Minimum Clearance to Non-Combustibles
From
Unit (with Heat Shield)
Unit
A B
H300 min. 0" (0 mm) 15" (381 mm)
max. 9" (228 mm)
Min. Mantel Height:
48" 1219 mm
Max. Mantel Depth:
12" 305 mm
60" (1524 mm)
with side load door