Hampton Direct H300 User Manual

Page of 32
Hampton H300 Cast Freestanding Woodstove
8
INSTALLATION
Residential Installation “C” Vent  (Single Wall)
 
Unit (with Heat Shield) 
       From Unit                           From          
From Flue Center-Line                   
 
 
 
 
 
          Corner                    
 
 
 
    A 
        B 
           C 
               D                     E 
           F
 
 
H300 
                                        17" (431 mm)  15" (381 mm)   13" (330 mm)   30" (762 mm)    15" (381 mm)      19" (483 mm)
Residential  Close Clearance (To be installed with required pipe components)
When the stove is installed as a close clearance residential unit, a listed double wall connector is required from the stove collar to the ceiling 
level.
 
Unit (with Heat Shield) 
       From Unit                            From            
   From Flue Center-Line                 
 
 
 
 
 
           Corner                         
 
 
 
          B 
               C                    D 
    E 
            F
   
 H300 
                                         15" (381 mm)   10" (254 mm)     9" (228 mm)    28" (711 mm)    10" (254 mm)   15" (381 mm) 
Mobile Home Close Clearance (To be installed with required pipe components)
"C" Vent single wall pipe is not approved for Mobile Home installations. (Refer to Mobile Home section).   
 
Unit (with Heat Shield) 
       From Unit                              From           
     From Flue Center-Line 
 
 
 
 
 
                                Corner                        
 
 
 
           B 
                  C 
       E 
                  F
 
H300                                                         15" (381 mm)      10" (254 mm)      9" (228 mm)    28" (711 mm)   10" (254 mm)    15" (381 mm)
 
 
 
 
 
 
                      
MINIMUM CLEARANCE TO 
COMBUSTIBLE MATERIALS
Please read the section below carefully. Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner, and from the 
rear heat shield to a back wall.
Clearances may only be reduced by means approved by the regulatory authority.
* Minimum clearance with 
side load door in use is 18" 
(457mm) to side wall or refer 
to dimension (A) if side load 
door is not used.