Note:  The recommended method for setting the POR signals is to use external pull up/down resistors 
(e.g. 4k7 
Ω) in which case the timing of the POR signals is not critical. 
See section 6.3 and 6.4 for further information on the operation of the status/ power on configuration 
interface and section 10.5 for timing details. 
5.7  POWER, GROUND, PLL AND LVDS SIGNALS 
5.7.1 General 
The Power, Ground and special signal connections are listed in Table 5-7. 
Table 5-7 Power, Ground and Special Signals 
Signal Dir 
Description 
Signal 
Type 
Power 
3.3 V power for the device 
3V3 
Ground 
Ground connection for the device 
GND 
VCOBias 
 
PLL VCO Bias 
analogue 
VSSPLL 
 PLL 
Supply 
3V3 
VDDPLL 
 PLL 
Supply 
GND 
LoopFilter   
PLL Loop Filter  
analogue 
LVDSref 
 
LVDS Buffer reference  
analogue 
 
5.7.2 Decoupling 
The power pins should be decoupled to the ground plane. One 100 nF decoupling capacitor should be 
used for each power pin. 
5.7.3  LVDS Reference  
An external resistor is required to provide a reference for the LVDS buffers. A resistor with a value 
between 16.3 k
Ω and 16.7 kΩ must be connected between LVDSref and ground. 
5.7.4  PLL External Components 
An internal PLL is used to provide the base transmit clock signal for the SpaceWire interfaces from the 
CLK input. External components are required to implement the PLL loop filter and to provide a bias for 
the PLL VCO. These components are illustrated in Figure 5-3. Note that R
VCO
, C and C0 are all 
connected to a quiet common ground track.