Dynojet Research Microphone 200iP User Manual

Page of 40
Air Brake and EEC Kit Installation Guide for 200i/250i and 200iP/250iP Motorcycle Dynamometers
A I R   B R A K E   A N D   E E C   K I T
Door Safety Switch
     
32
5
Loosen the screws that hold the jumper wires in place and remove the wire.
6
Route the black and yellow wire from the door safety switch through the dyno.
Make sure the switch will not get caught in any moving components or chafed on 
any edges.
7
Attach the yellow wire to the 1A position on the J2 connector.
8
Attach the black wire to the 6B position on the J4 connector.
Figure 32: Wiring the Door Safety Switch
9
Replace the CPI cover using the screws removed earlier.
10 The door safety switch needs to be mounted at the entry of the dyno room.
11 Plug the dyno into the power outlet.
12 Turn on the main breaker inside the power distribution assembly door.
13 Open the door safety switch by allowing the plunger to extend.
The air brake should be applied holding the drum and the status light on the 
Control Panel will be flashing.
14 Depress the door safety switch and the air brake will release and the status light 
will be on steady.
black wire to 6B 
on J4 connector
yellow wire to 1A 
on J2 connector
remove 
jumper 
wire