D1: AMP STATUS 
The Turbo Clipper Drive utilizes a scrolling single-digit 7-segment display to exhibit faults to the 
outside world. When control and DC bus power are applied, the Drive will display a solid dot 
indicating that the software and hardware are running normally. 
 
Error Codes 
Display  Description 
Global Faults
 
 
Under Voltage Fault: 
Indicates that the bus voltage is not present or less than 12Volts 
 
Over Voltage Fault: 
Indicates that the bus voltage has exceeded 60Volts 
 
Over Temperature Fault:  
Indicates that the Board  has exceeded 65°C 
Axis n Faults (n=1 thru 4) 
n
 
Axis n Over load Fault: 
Indicates that the current rating (5/15A) of the drive has been exceeded 
n
 
Axis n Over Current Fault:  
Indicates that the peak current value has exceeded the permissible limit(20Amps)