Delta Tau GEO BRICK LV Reference Manual

Page of 760
Turbo PMAC/PMAC2 Software Reference
 
Turbo PMAC Program Command Specification 
 421 
Examples: 
LINEAR  
; Linear interpolation mode 
X10Y0 F2 
; Linear move 
CIRCLE2 
; Counterclockwise circular interpolation mode 
X20 Y10 J10 
; Arc of 10-unit radius 
X15 Y15 I-5 
; Arc of 5-unit radius 
CIRCLE1 
; Clockwise circle mode 
X5 Y25 J10 
; Arc move of 10-unit radius 
See Also: 
Circular Moves (Writing and Executing Motion Programs) 
I-variable Isx13 
Program commands NORMALCIRCLE1LINEARPVTRAPIDSPLINE1
{axis}{data}{vector}{data} 
COMMANDx"{command}"  
Function: 
Command issuance from internal program 
Type: 
Motion program (PROG and ROT); PLC program 
Syntax: 
COMMAND "{command}" 
 
CMD "{command}" 
 
COMMANDS "{command}" 
 
CMDS "{command}" 
 
COMMANDP "{command}" 
 
CMDP "{command}" 
 
COMMANDR "{command}" 
 
CMDR "{command}" 
 
COMMANDA "{command}" 
 
CMDA"{command}" 
This statement causes the program to issue a command to Turbo PMAC as if it came from the host 
(except for addressing modes and response direction).   
If there is a motor- or coordinate-system-specifier (#n or &n) within the quoted string, a motor- or 
coordinate-system-specific command will be directed to that motor or coordinate system.  If there is no 
specifier, a motor- or coordinate-system-specific command will be directed to the first motor or 
coordinate system.  Any specifier within a COMMAND statement is not modal; it does not affect the host 
addressing specifications or the modal addressing of any program, including its own. 
Any data or error response for the command given inside the quote marks is directed to the port specified 
by the letter at the end of COMMAND
 
COMMAND provides no response to any port 
 
COMMANDS provides a response to the main serial port 
 
COMMANDP provides a response to the parallel bus port 
 
COMMANDR provides a response to the DPRAM ASCII response buffer 
 
COMMANDA provides a response to the Option 9T auxiliary serial port 
If I62=0, Turbo PMAC issues a carriage-return (<CR>) character automatically at the end of any data 
response to the command.  If I62=1, Turbo PMAC does not issue a <CR> character at the end of the data 
response; a SEND^M must be used to issue an <CR> in this case. 
Each PLC program has its own addressing mode for both motors and coordinate systems, independent of 
each other and independent of the host addressing modes.  These are controlled by the PLC program 
ADDRESS command.  This modal addressing affects commands issued from within a PLC program that