Turbo PMAC Global I-Variables 
 85 
Ixx03  Motor xx Position Loop Feedback Address 
Range:   
$000000 - $FFFFFF 
Units:    
Turbo PMAC Addresses 
Turbo PMAC/PMAC2 Ixx03 Defaults 
Ixx03 
Value 
Register 
Ixx03 
Value 
Register 
I103 
$003501 
Conversion Table Line 0 
I1703 
$003511 
Conversion Table Line 16 
I203 
$003502 
Conversion Table Line 1 
I1803 
$003512 
Conversion Table Line 17 
I303 
$003503 
Conversion Table Line 2 
I1903 
$003513 
Conversion Table Line 18 
I403 
$003504 
Conversion Table Line 3 
I2003 
$003514 
Conversion Table Line 19 
I503 
$003505 
Conversion Table Line 4 
I2103 
$003515 
Conversion Table Line 20 
I603 
$003506 
Conversion Table Line 5 
I2203 
$003516 
Conversion Table Line 21 
I703 
$003507 
Conversion Table Line 6 
I2303 
$003517 
Conversion Table Line 22 
I803 
$003508 
Conversion Table Line 7 
I2403 
$003518 
Conversion Table Line 23 
I903 
$003509 
Conversion Table Line 8 
I2503 
$003519 
Conversion Table Line 24 
I1003 
$00350A 
Conversion Table Line 9 
I2603 
$00351A 
Conversion Table Line 25 
I1103 
$00350B 
Conversion Table Line 10 
I2703 
$00351B 
Conversion Table Line 26 
I1203 
$00350C 
Conversion Table Line 11 
I2803 
$00351C 
Conversion Table Line 27 
I1303 
$00350D 
Conversion Table Line 12 
I2903 
$00351D 
Conversion Table Line 28 
I1403 
$00350E 
Conversion Table Line 13 
I3003 
$00351E 
Conversion Table Line 29 
I1503 
$00350F 
Conversion Table Line 14 
I3103 
$00351F 
Conversion Table Line 30 
I1603 
$003510 
Conversion Table Line 15 
I3203 
$003520 
Conversion Table Line 31 
Turbo PMAC2 Ultralite Ixx03 Defaults 
Ixx03 
Value 
Register 
Ixx03 
Value 
Register 
I103 
$003502 
Conversion Table Line 1 
I1703 
$003522 
Conversion Table Line 33 
I203 
$003504 
Conversion Table Line 3 
I1803 
$003524 
Conversion Table Line 35 
I303 
$003506 
Conversion Table Line 5 
I1903 
$003526 
Conversion Table Line 37 
I403 
$003508 
Conversion Table Line 7 
I2003 
$003528 
Conversion Table Line 39 
I503 
$00350A 
Conversion Table Line 9 
I2103 
$00352A 
Conversion Table Line 41 
I603 
$00350C 
Conversion Table Line 11 
I2203 
$00352C 
Conversion Table Line 43 
I703 
$00350E 
Conversion Table Line 13 
I2303 
$00352E 
Conversion Table Line 45 
I803 
$003510 
Conversion Table Line 15 
I2403 
$003530 
Conversion Table Line 47 
I903 
$003512 
Conversion Table Line 17 
I2503 
$003532 
Conversion Table Line 49 
I1003 
$003514 
Conversion Table Line 19 
I2603 
$003534 
Conversion Table Line 51 
I1103 
$003516 
Conversion Table Line 21 
I2703 
$003536 
Conversion Table Line 53 
I1203 
$003518 
Conversion Table Line 23 
I2803 
$003538 
Conversion Table Line 55 
I1303 
$00351A 
Conversion Table Line 25 
I2903 
$00353A 
Conversion Table Line 57 
I1403 
$00351C 
Conversion Table Line 27 
I3003 
$00353C 
Conversion Table Line 59 
I1503 
$00351E 
Conversion Table Line 29 
I3103 
$00353E 
Conversion Table Line 61 
I1603 
$003520 
Conversion Table Line 31 
I3203 
$003540 
Conversion Table Line 63 
Ixx03 tells the Turbo PMAC where to look for its position feedback value to close the position loop for 
Motor xx.  It contains the address of the register where the motor will read its position feedback value.   
Usually this is a result register in the “Encoder Conversion Table”, where raw feedback values have been 
pre-processed at the beginning of each servo cycle.  Feedback data is expected in units of 1/32 count (5 
bits of fractional data).  The result registers in the Encoder Conversion Table are located at addresses 
X:$003501 to X:$0035C0, corresponding to table setup I-variables I8000 to I8191, respectively. 
For a control loop with dual feedback, motor and load, use Ixx03 to point to the encoder on the load, and 
Ixx04 to point to the encoder on the motor.