 114 
Absolute Power-On Position Read (Technique 3) 
With  Technique  3,  the  absolute  power-on  read  can  be  performed  using  PMAC’s  automatic  settings 
(Ixx80, Ixx10 and Ixx95). 
 
Example 1: Channel 1 driving a 32-bit (20-bit single turn, 12-bit multi-turn) rotary serial encoder: 
I180=2   
 
 
; Absolute power-on read enabled 
I110=$78B20 
 
 
; Absolute power-on position address (ch1 serial data register A) 
I195=$A00000 
 
 
; Parallel Read, 32 bits, Signed, from Y-Register –User Input 
 
Bit 23: =1 Signed
      
    =0 Unsigned
1 0 1 0 0 0 0 0
Bit 22: =1 X-Register
            =0 Y-Register
Bits16-21: Number of Bits to read
(Resolution 32 bits or 100000 )
Ixx95
Binary:
Hex($):
A
0
0 0 0 0 0 0 0 0
0
0
0 0 0 0 0 0 0 0
0
0
Bits 0-15: reserved
(always 0)
 
In this mode, PMAC reads and reports 32 bits from the consecutive serial data registers: 
Serial Data Register A
(Ch1 Y:$78B20)
Serial Data Register B
(Ch1 Y:$78B21)
32 bits
0
23
47
 
With the setting of Ixx80=2, the actual position is reported automatically on Power-up. Otherwise, a #1$* 
command is necessary to read and report the absolute position. 
 
Example 2: Channel 1 driving a 20-bit (20-bit Singleturn, No Multiturn) absolute rotary serial  encoder, 
or a similar protocol resolution (20 bits) linear scale: 
I180=2   
 
 
; Absolute power-on read enabled 
I110=$78B20 
 
 
; Absolute power-on position address (ch1 serial data register A) 
I195=$140000 
 
 
; Parallel Read, 20 bits, Unsigned, from Y-Register –User Input 
 
Bit 23: =1 Signed
      
    =0 Unsigned
0 0 0 1 0 1 0 0
Bit 22: =1 X-Register
            =0 Y-Register
Bits16-21: Number of Bits to read
(Resolution 20 bits or 010100 )
Ixx95
Binary:
Hex($):
1
4
0 0 0 0 0 0 0 0
0
0
0 0 0 0 0 0 0 0
0
0
Bits 0-15: reserved
(always 0)
 
In this mode, PMAC reads and reports 20 bits from the first serial data register: 
Serial Data Register A
(Ch1 Y:$78B20)
Serial Data Register B
(Ch1 Y:$78B21)
20 bits
0
23
47
 
With the setting of Ixx80=2, the actual position is reported automatically on Power-up. Otherwise, a #1$* 
command is necessary to read and report the absolute position.