Siemens Camera Accessories 6DS2-510-0xx00-0xa0 User Manual

Page of 20
Product Information 
 
February, 1999 
BRIDGE CS-L2 
Copyright © SIEMENS AG 1996-1999. All Rights Reserved.
 
S79220-A0978-A-05-7637
 
Page 4 of 20 
 
 
2.2 Procedure for Upgrade to V02.01 with Programming Device PG740 
Switch off the power supply of the BRIDGE CS-L2 before pulling the memory card! 
 
For the upgrade, insert the memory card into the MEM-CARD slot of the PG740. Now start 
the batch UPGRADE.BAT (if applicable, information on the memory card drive, default 
setting is E:): 
This batch file 
creates a directory C:\UPGRADE.201 (for this, at least 1 MByte must be free on drive 
C:). 
copies all files from memory card into the upgrade directory. 
deletes the RMOS system file, as this can never be copied to the MC. 
deletes all BAK files. 
copies the packed upgrade files from disk into the directory (the system files to be 
upgraded are then overwritten). 
reformats the memory card and sets up the RMOS system. 
copies all files from the upgrade directory to the memory card 
 
Now perform the following two steps: 
1)  Put the upgraded memory card in the allocated Bridge CS-L2 and initiate a reboot of 
the CPU (power on). 
2)  Install the new terminal program ASBEDIEN V1.06 to your PC from the diskette 
included with your delivery (IBS tools). 
 
 
Notes: 
 
The upgrade batch runs under Windows 95 and 3.1, but not under Windows NT ! 
 
Subdirectories on the Memory Card will not be copied. These have to be saved to the PC/ 
Programming device bevor starting the upgrade procedure. 
 
The upgrade directory is not deleted. This means that, if an error should occur during the 
upgrade process, the process can be repeated. 
Attention:  If more than one Bridge memory card are upgraded the directory 
UPGRADE.201 must either be deleted or renamed between the individual 
upgrade processes. 
 
The upgrade directory can also be used as a backup copy of the entire system software. 
This means that repairs can be carried out on memory cards with defective software 
(create directory UPGRADE.200, copy backed up file to it and start the batch file).