Avanti Security Camera K-600HW User Manual

Page of 8
 
 
1.8 
Test & Commission. 
 
After the wiring has been completed re-connect the 
battery to the terminals marked Batt  +  - 
The panel will now go into alarm condition, enter user 
code (0123) to silence, the Tamper and Power will be lit 
and Day & Zone LED’s flashing. 
To reset the panel re-enter the user code and the Day & 
Power LED’s will be steady (DAY mode). 
Re-fit the lower cover and the system should now be 
tested to ensure correct operation. 
 
2 Descriptions 
 
2.1 Zones 
 
Avanti panels come supplied with service links fitted to 
the zone terminals to simulate a closed circuit. As each 
zone is connected these links should be removed. All 
zones are fully programmable. 
 
Zone Functions per Program:
 
Immediate – This function would be used when the 
zone is not part of an entry/exit route. When the system 
is SET activation of an immediate zone will cause a full 
alarm condition. 
 
Timed – A timed zone would be used to protect an 
entry/exit route. Opening the door or triggering the 
sensor in this type of zone when the system is SET will 
start the entry timer. 
 
Time Inhibited – A time inhibited zone operates as an 
immediate zone unless a timed zone has been operated 
and a timer started. Such a zone would be utilised to 
allow passage between the entry/exit door and the control 
panel when there are detectors present. 
 
Fire – If you choose to utilise a zone as a fire zone then 
no other devices may be wired into this zone. Therefore a 
zone cannot be both fire and intruder. 
 
Doorbell –this feature can be programmed into any 
zone. A doorbell will not operate whilst the entry/exit 
timers have started, when the system is in full alarm 
condition or whilst in programming mode. 
 
Exit Modes per Program: 
Timed Exit
 – a timed program will SET once the exit 
timer has expired. 
 
Final Door Set – a final door program will SET 5 
seconds after the final door has been opened and closed. 
 
Immediate/Silent Set – an immediate program will 
SET the system immediately and silently. 
 
2.2 Tamper 
 
Avanti panels come supplied with a service link fitted to 
the Tamper terminals; this should be removed as the 
tamper circuit is wired. 
Tamper circuits must be wired in series
If a Tamper occurs whilst the system is in DAY mode 
then only the internal sounders will be activated.  
If a Tamper occurs whilst the system is SET then both the 
internal and external sounders will be activated. (If you 
are using an RS Panel fitted with a communicator then a 
signal will also be sent to an Alarm Receiving Centre 
(ARC). 
 
2.3 PA 
 
Remove the service link and wire in series any number of 
PA buttons to the PA terminals. Activation of the PA will 
cause the system to go into a full alarm condition whether 
in DAY mode or SET. (If you are using an RS Panel 
fitted with a communicator then a signal will also be sent) 
 
2.4 
Bell output & Strobe 
 
Connect the wires from the bell to the terminals D (bell 
positive) and B (bell negative).  
The bell tamper should be wired to the T A terminals and 
the service link removed. 
Wire the strobe to the terminals marked strobe observing 
the correct polarity. 
When fitting a combined sounder/strobe unit follow 
manufactures instructions. 
• 
T                -Ve tamper return 
• 
A                -Ve supply (0V) 
• 
B                -Ve sounder trigger 
• 
D               +Ve supply (12V) 
 
2.5 Internal 
sounder 
 
A maximum of two 16 ohm extension speakers may be 
wired in parallel to the terminals marked        The 
volume of both the internal sounder and entry/exit timers 
can be adjusted by a pre-set located on the PCB. 
 
2.6 Set 
 
This output becomes 12V positive on SET and is removed 
on commencement of the entry timer. 
 
 
2.7 13V 
Supply 
 
This terminal provides a 13.8V output to power detectors 
and shock sensors etc. Total current available is 350 mA. 
 
2.8 PTS 
 
The PTS terminals can be programmed to be either 
PUSH TO SET
 (PTS) or KEYSWITCH operation. 
 
PTS – operation of an exit terminate button when exiting 
the property will cause the timer to expire immediately 
and the system will become SET
 
Keyswitch – this enables the system to be SET and 
UNSET with the use of a keyswitch. If the panel needs to 
be reset then a user code must be entered.  
 
2.9 Battery 
 
To ensure continuing protection in the event of mains 
power failure a suitable rechargeable battery with a 
capacity to support the system for a period of 12 hours 
must be fitted.  
 
NOTE: Calculations made for Avanti Compact with 
onboard keypad using a neon sounder, assuming 1 
complete alarm cycle of 20 minutes. 
Battery Backup Time Vs. Number of Passives (Passive 
Current=15ma)
4
9
14
19
1
2
3
4
5
6
7
8
Number of Passives
Backup Time in Hours
1.2Ah Battery
2.1Ah Battery
Battery Backup Time Vs. Number of Passives (Passive 
Current=10ma)
4
9
14
19
1
2
3
4
5
6
7
8
Number of Passives
Backup Time in Hours
1.2Ah Battery
2.1Ah Battery