Avanti Security Camera K-600HW User Manual

Page of 8
 
 
3 Operation 
 
3.1 Programs 
 
The Avanti provides the facility for up to 3 programs that 
can be selected by entering the AB or * keys after 
entering the user code when setting the system. The * 
program is used for Full Set. If no program is selected 
when setting the system the Avanti will default to 
Program *.  
When setting up the programs the function of each zone 
can be changed i.e.: - Immediate, Timed, Time Inhibited 
or Exit mode. 
 
3.2 Operating 
 
Setting the System 
To set the system a user code (4 digits) must be entered 
and a program selected (A,B or * [Full Set]). If no 
program is selected within 5 seconds then the Avanti will 
default to Program (Full Set). 
The exit timer will begin and a series of bleeps will sound. 
 
Unsetting the System 
To UNSET the system a user code must be entered, this 
will return the panel to DAY mode. If the external siren is 
sounding then entering the user code will silence the 
sounder. All that is required to reset the system is to 
enter a user code. 
 
Fault during setting 
If the system is unable to SET then the internal sounders 
will make a different bleeping sound. The fault on the 
system will be indicated by the relevant zone/PA/tamper 
LED being lit. 
 
Omitting Zones  
To omit a zone a user code must be entered followed by 
Z and then the zone number(s) to be omitted. The 
zone(s) chosen to be omitted will be indicated by the 
relevant zone LED being toggled off. A program should 
then be selected. If a program is not selected then the 
panel will default to Program *
 
Quick Set 
This feature allows the panel to be SET so that it 
overrides the programmed exit time. Entering a User 
code, selecting Program A/B or * and then pressing  
‘
will cause the
 
panel to SET within 2 seconds.  
 
 
 
 
3.3 Access 
Codes 
 
Avanti has the following access codes: 
1x Engineer Access code.            1x Holiday Access code. 
1x Manager Access code             4x User Access codes. 
Engineer Access Code – cannot be used to SET or 
UNSET the panel, it can only be used to configure the 
system and view the Event Log. Therefore it can only be 
used from within DAY mode. 
Manager Access Code – is used to SET and UNSET the 
system. It also has the ability to change all other access 
codes except for the engineers. The Manager is also able 
to view the Event Log, test the system and programme 
Chime for any zone.  
Holiday Access Code – the purpose of this code is to 
allow access to the property whilst the manager is absent. 
The Holiday Access Code is programmed by the Manager 
and is only valid until the Manager UNSETS the system. 
At this point the Holiday Access Code becomes invalid and 
is no longer accepted by the control panel. 
User Access Code – allows the User to SET and UNSET 
the system. Any User can also program Chime. 
 
Additionally RS Panels have individual duress codes for 
the Users, Holiday and Manager. 
Duress is only accessible in SET. Entering a user code 
followed by the first digit within 1 to 1.5 seconds will 
activate a silent PA. i.e.: - 0 1 2 3 0  
 
3.4 Keypad 
tamper 
 
When the control panel is in SET, the Keypad tamper will 
be activated after 20 invalid key presses. A full alarm 
condition will then be created. (If you are using an RS 
Panel fitted with a communicator then a signal will also 
be sent.) 
 
3.5 
Entry Exit timers 
 
The entry and exit timers have been factory set for 30 
seconds. If you require more or less time then these 
timers can be programmed independently via the keypad 
in increments of 1 second from immediate to 99 seconds. 
 
3.6 
On Board PA 
 
Simultaneously depressing key’s 4 and 8 will activate a 
PA thus creating a full alarm condition. This feature can 
be used when the system is in DAY mode or SET. (If you 
are using an RS Panel fitted with a communicator then a 
signal will also be sent.) 
 
 
3.7 Service 
timer 
 
The Avanti has provision for a service timer, which once 
selected is fixed at 900 closings. When expired the 
tamper LED will flash intermittently. The expiration of the 
service timer will not disable the control panel. 
 
3.8 
Non Volatile Memory (NVM) 
 
The NVM circuit stores and protects the access codes and 
system configuration information. To clear there are two 
methods. i.e.: - 
 
Method 1  From engineering mode pressing * twice 
within 2 seconds will cause the panel to revert to factory 
defaults whilst retaining the engineers access code. 
 
Method 2  Remove power and remove link/wires 
between T and A. Link Set+ to T with lid tamper closed 
and power up the panel. The Avanti will retain all 
information but will clear the engineer and manager 
access codes.  
 
3.9 
Confirmed alarms (RS models only) 
 
To reduce the level of false alarms the Avanti will only 
send a confirmed signal to an Alarm Receiving Centre 
(ARC) when 2 or more zones have been activated 
sequentially. 
 
3.10 Double 
knock 
 
The Avanti range of panels can be programmed for 
double knock. When a zone is activated a 10 minute timer 
will begin, if during this time the same or another zone is 
activated a full alarm condition will be caused. A zone 
active for 10 seconds will also cause an alarm condition. 
 
3.11 Bell 
follow 
 
Bell Follow Off – If the system is activated then once 
the bell has expired the strobe will continue to flash until 
the system is reset. 
 
Bell Follow On – If an alarm condition is caused then 
the strobe will cease to flash at the same time as the bell 
stops sounding.