Avanti Security Camera K-600HW User Manual

Page of 8
 
 
4.2 
Setting Up Zone Attributes. 
 
Set-up Zone Attributes menu is entered from the 
Engineers menu, by pressing Key 2
 
Each of the zones has 9 Attributes that dictate its 
function, that are fixed regardless of what the program 
set-up has. 
 
On entering the set-up Zone Attributes menu, the Day 
LED will flash, along with all 8 zone LED’s. This is to 
prompt the engineer to select the zone number for 
which to set the attributes. 
 
Once the zone number is entered, the Day LED will stop 
flashing and the zone LED’s will be lit according to the 
zone attributes that are selected. The attributes are as 
follows: 
 
Zone LED 1 – On for Chime. (Key 1
Zone LED 2 – On for OMIT. (Key 2
Zone LED 3 – On for double knock. (Key 3
Zone LED 4 – On for normally open loop. (Key 4
Zone LED 5 – On for Fire Zone. (Key 5
Zone LED 6 – On for Doorbell. (Key 6
Zone LED 7 – Not Used. 
Zone LED 8 – On for zone disabled. (Key 8
Tamper LED – On for Utility output A. (Key 9
PA LED – On for Utility output B. (Key 0
 
Pressing the Key number that represents the LED number 
will toggle that attribute. 
 
Press A To Accept / Press B To Abort the changes. 
 
This will then return the engineer back to the Engineers 
Menu. 
 
4.3 
Setting Up the Exit timer. 
 
Set-up Exit Timer menu is entered from the Engineers 
menu by pressing Key 3
 
The Exit timer may be programmed from 0 seconds to 99 
seconds. 
On entering the set-up Exit timer menu, the Day LED will 
be extinguished, and Zone 1 & 2 LED’s will light, to 
prompt for a 2-digit number between 00 and 99 for the 
Exit time in seconds. Once the 2-digit time has been 
entered, the PA and TAMPER LED will flash prompting 
the engineer to:
 
 
Press A To Accept / Press To Abort the changes. 
 
 
4.4 
Setting Up the Entry timer. 
 
Set-up Entry Timer menu is entered from the Engineers 
menu, by pressing Key 4
 
The entry timer may be programmed from 0 seconds to 
99 seconds. 
 
On entering the set-up Entry Timer menu, the Day LED 
will be extinguished, and Zone 1 & 2 LED’s will light, to 
prompt for a 2-digit number between 00 and 99 for the 
Entry time in seconds. Once the 2-digit time has been 
entered, the PA and TAMPER LED will flash prompting 
the engineer to: 
 
Press A To Accept / Press B To Abort the changes. 
 
4.5 
Setting Up the Bell Active timer. 
 
Set-up Bell Active Timer menu is entered from the 
Engineers menu, by pressing Key 5
 
The Bell Active Timer may be programmed from 0 Minutes 
to 99 Minutes. 
 
On entering the set-up Bell Active Timer menu, the Day 
LED will be extinguished, and zone 1 & 2 LED’s will light, 
to prompt for a 2-digit number between 00 and 99 for the 
Bell Active time in minutes. Once the 2-digit time has 
been entered, the PA and TAMPER LED will flash 
prompting the engineer to:
 
 
Press A To Accept / Press B To Abort the changes. 
 
4.6 
Setting Up the Bell Delay timer. 
 
Set-up Bell Delay Timer menu is entered from the 
Engineers menu, by pressing Key 6
 
The Bell Delay Timer may be programmed from 0 Minutes 
to 99 Minutes. 
 
On entering the set-up Bell Delay Timer menu, the Day 
LED will be extinguished, and zone 1 & 2 LED’s will light, 
to prompt for a 2-digit number between 00 and 99 for the 
Bell Delay time in minutes. Once the 2-digit time has been 
entered, the PA and TAMPER LED will flash prompting 
the engineer to:
 
 
Press A To Accept / Press B To Abort the changes. 
 
 
 
 
 
 
4.7 
Programming Access codes. 
 
Programming Access Codes is entered from the Engineers 
menu by pressing Key
 
7 
 
Once the Programming Access codes menu has been 
entered then the Access code to be changed must be 
selected. The Day LED and zone LED’s 1 to 7 will flash to 
prompt the selection of access codes 1 to 7. The access 
codes are selected as follows: 
 
Press 1 To Program User Access code 1.
 
Press 2 To Program User Access code 2.
 
Press 3 To Program User Access code 3.
 
Press 4 To Program User Access code 4.
 
Press 5 To Program the Holiday code.
 
Press 6 To Program the Manager code.
 
Press 7 To Program the Engineer code.
 
 
Once the Access code to change has been selected, the 
Day LED will light constantly, and zone LED’s 1 to 4 will 
light to prompt for the 4 digit access code to be entered. 
For every key pressed, 1 zone LED will be extinguished, 
indicating the number of digits left to enter of the access 
code. 
 
Once all 4 digits of the access code have been entered, all 
of the zone LED’s will be extinguished, and the PA and 
Tamper LED’s will be flashing. 
 
Press A To Accept / Press B To Abort the changes. 
 
4.8 
Setting Up the Service timer. 
 
Set-up Service Timer menu is entered from the Engineers 
menu by pressing KEY 8
 
The service timer is pre-set to 900 closings. The engineer 
has the option of: 
1.  Enable or disabling the service timer. 
2.  Resetting the service timer. 
 
On entering the service timer menu the zone LED’s have 
the following meaning: 
 
LED 1 Service Timer enabled.  
LED 2 Service Timer disabled. 
LED 3 Service Timer Expired. 
 
Press  1 To Enable the service timer.
 
Press  2 To Disable the service timer.
 
Press  3 To Reset and enable the service timer.
 
 
Once a key has been pressed, there will be an 
acknowledgement bleep, and then the panel will be 
returned back to the engineers menu.