Residen  al Electric Water Heater Use and Care Guide • 17
TROUBLESHOOTING
TR
OUBLE
SHOO
TING
PROBLEM  
POSSIBLE CAUSE(S) 
CORRECTIVE ACTION 
 
See explanaons on the following pages. 
NO HOT WATER  
• No power to water heater  
Check for blown fuses or tripped circuit breaker.
(page 18) 
   
Check for power.
 
• Burned out upper heang element (Dry Fired) 
Replace upper heang element.
 
• Energy Cut Off Switch tripped 
See page 19, step 5.
 
• Faulty Thermostac Mixing Valve 
Check hot water at other faucets.
 
• Non-Funconing upper thermostat  
Check/replace upper thermostat. (See page 23)
 
• Leak in plumbing system 
Check hot water side of home’s plumbing system
  
 
for 
leaks. 
INSUFFICIENT HOT WATER  
• Thermostats set too low 
Set thermostats to desired temperature.
(page 19) 
   
See page 15.
 
• Non-Funconing lower heang element 
Replace lower heang element. (See page 22)
 
• Water heater’s capacity too small (or usage too high) 
Install adequately sized water heater
 
   
(or reduce usage).
 
• Thermostac Mixing Valve faulty/set too low 
Check hot water at other faucets.
 
• Non-Funconing lower thermostat 
Replace lower thermostat. (See page 23) 
 
• Hot and cold pipe connecons reversed 
Correct piping.
 
• Leak in plumbing system 
Check hot water side of home’s plumbing system
  
 
for 
leaks.
 
• Melted dip tube 
Check/replace dip tube.
SLOW HOT WATER RECOVERY  
• Low supply voltage 
Check power (voltage).
(page 19) 
 
 
• Malfunconing lower heang element 
Check lower element and replace if burned out.
 
   
(See page 22)
TEMPERATURE TOO HIGH 
• Non-funconing thermostat  
Replace thermostat. (See page 23)
 (page 20) 
 
• Grounded/shorted heang element 
Replace heang element. (See page 22)
 
• Thermostac Mixing Valve faulty/set too high 
Check hot water at other faucets.
LOW WATER PRESSURE (page 20)   • Parally closed supply valve.  
See Low Water Pressure secon on page 20.
DRIPS FROM T&P RELIEF VALVE   • Excessive water pressure 
Use Pressure Reducing Valve set to 50-60 psi.
(page 20)
 
• Thermal expansion 
Install a Thermal Expansion Tank. 
 
• Debris under valve seat 
See page 20. 
WATER ODOR (page 20)  
• Bacteria in the water  
See Water Odor secon on page 20.