SCI Scandicrafts A2840/R User Manual

Page of 20
5
UNPLUG THE UNIT BEFORE PERFORMING ANY MAINTENANCE PROCEDURES
Recommended Monthly Maintenance
• Clean the Primary Filter
• Clean the Purifier Plate
• Clean the Catalytic Screen
PRIMARY FILTER & CATALYTIC SCREEN CLEANING
You have three options to clean the Primary filter and the Catalytic Screen:
1.  When visibly dirty or after 30 days, remove the primary filter and the catalytic screen 
from the unit. With a hand-held vacuum, remove the heavy particulates from both  
filters. This method will extend the life of the filters and ensure proper function of the 
catalytic screen.
2. If vacuuming does not clean the filter sufficiently, remove the primary filter and the 
catalytic screen from the unit and wash them in warm water. Brush gently with a 
toothbrush to remove particulates. Allow to dry thoroughly before re-installing.
NOTE: Do not use soap because it could damage the filters.
3. If a replacement or additional filter and/or catalytic screen are needed, contact the  
dealer you purchased your product from or visit www.rppurchase.com to locate your  
closest dealer.
CLEANING THE PURIFICATION PLATE
1. Remove the Purification Plate (see Purification Plate and Catalytic Screen Removal below).
2. Wash the Purification Plate with about 1 drop of mild dish soap (per side) and a toothbrush.
3. Use the toothbrush to make small circular motions over all of the metal mesh areas.
Be careful not to drop or break the Purification Plate while cleaning.
4. Rinse with water and allow it to air dry completely before reinstalling.
PRIMARY FILTER REMOVAL
1.  Unplug the power to the unit.
2. Unscrew the four rear corner screws from the Primary filter and pull the filter handle   
to remove. 
Refer to Diagram A
3. After servicing Primary filter, place it back in its original position and re-install the  
four corner screws.
PURIFICATION PLATE AND CATALYTIC SCREEN REMOVAL
1. Remove Primary filter.
2. Carefully remove the Purification Plate pulling it straight out. This is an ideal time to   
clean the Purification Plate.
Refer to Diagram B.
3. Gently pull the Catalytic Screen handle to remove it for cleaning.
Refer to Diagram C.
4. After servicing Catalytic Screen, place it back in its original position by placing the  
bottom of screen in first.
5. Carefully re-insert the Purification Plate into its original position.  Make sure the  
Purification Plate is fully inserted.
6.  Place the Primary filter back in its original position and re-install the four corner screws.
GENERAL MAINTENANCE
I-4506 BR7580R-1  6/25/07  7:57 AM  Page 11