2.5.8  Oil Pressure Gauge Type 
The EMS100 comes from the factory preprogrammed with the characteristics of oil pressure 
gauge types for supported engines. If the EMS100 is used with an analog oil pressure gauge, 
you must select the correct type of gauge for this setting in order for the data to be displayed 
correctly.  If you have no oil pressure gauge present, select the “No Gauge” option for this 
setting. 
 
2.5.9  Oil Pressure Sender Type 
The EMS100 comes from the factory preprogrammed with the characteristics of oil pressure 
senders for supported engines.  If the engine to which you are connecting the EMS100 has a 
oil pressure sender, you must select the correct type of oil pressure sender for this setting in 
order for the data to be displayed correctly.  If you have no oil pressure sender present, select 
the “Disabled” option for this setting. 
 
2.5.10 Oil Pressure Sender Offset 
Often, the characteristics of individual oil pressure senders vary from their specified values.  
This setting allows you to apply an offset to the resistance value of the oil pressure sender in 
order to allow you to bring the digital value reported by the EMS100 into agreement with that 
displayed by the analog gauge. 
 
2.5.11 Water Temperature Gauge Type 
The EMS100 comes from the factory preprogrammed with the characteristics of water 
temperature gauge types for supported engines. If the EMS100 is used with an analog water 
temperature gauge, you must select the correct type of gauge for this setting in order for the 
data to be displayed correctly.  If you have no water temperature gauge present, select the “No 
Gauge” option for this setting. 
 
2.5.12 Water Temperature Sender Type 
The EMS100 comes from the factory preprogrammed with the characteristics of water 
temperature senders for supported engines.  If the engine to which you are connecting the 
EMS100 has a water temperature sender, you must select the correct type of water 
temperature sender for this setting in order for the data to be displayed correctly.  If you have 
no water temperature sender present, select the “Disabled” option for this setting. 
 
2.5.13 Water Temperature Sender Offset 
Often, the characteristics of individual water temperature senders vary from their specified 
values.  This setting allows you to apply an offset to the resistance value of the water 
temperature sender in order to allow you to bring the digital value reported by the EMS100 into 
agreement with that displayed by the analog gauge. 
 
2.5.14 Engine Hours 
The EMS100 reports engine hours based on how long the EMS100 has been powered from 
the engine.  The EMS100 comes from the factory preprogrammed with an engine hours 
reading of 0 hours.  If you are installing the EMS100 on an engine that has been in service, or