Maretron ENGINE MONITORING SYSTEM EMS100 User Manual

Page of 21
 
EMS100 User’s Manual  
 
 
 
 
 
 
Page 8  
 
Revision 1.1 
4  Troubleshooting 
If you notice unexpected operation of the Maretron EMS100, follow the troubleshooting 
procedures in this section to remedy simple problems. If these steps do not solve your 
problem, please contact Maretron Technical Support (refer to Section 0 for contact 
information). 
 
Symptom 
Troubleshooting Procedure 
No engine data visible 
on NMEA 2000
®
 
network. 
Ensure that the NMEA 2000
®
 network is operational by observing 
displays. You should see information from components besides the 
ones attached to the EMS100 which verifies an operational NMEA 
2000
®
 network. If you don’t see data, try disconnecting the NMEA 
2000 connection you made to the EMS100 as something may 
have been connected incorrectly. 
 
Ensure that the Maretron wiring harness is securely connected 
both to the EMS100 and to the existing engine wiring harness as 
directed in the instructions supplied with the Maretron wiring 
harness. 
 
Once you are sure that the NMEA 2000 network is operational with 
a connected EMS100, ensure that the NMEA 2000
®
 connector on 
the Maretron wiring harness is securely connected to the NMEA 
2000
®
 network. 
 
 
Ensure that the ignition switch for engine is turned on.  The 
EMS100 draws the majority of its power from the engine power 
connection. 
 
Ensure that the EMS100 is programmed with an appropriate 
engine NMEA 2000 instance as described in Section 2.5.1. 
 
Ensure that all NMEA 2000
®
 messages are enabled (see Section 
2.5.16 for details). 
Incorrect Engine Data 
Ensure that the settings for gauge type, sender type, and number 
of flywheel teeth are programmed appropriately. 
 
Check the values of sender offset programmed into the EMS100. 
Incorrect Tachometer 
Readings 
Check the adjustment of the tachometer sensor on the engine. 
Once the EMS100 is connected, you may need to adjust the 
spacing between the sensor and the flywheel teeth.  
 
Warning: There are no user-serviceable components inside the Maretron EMS100.  
Opening the EMS100 will expose the sensitive electronic components to adverse 
environmental conditions that may render the unit inoperative. Please do not open the