Overcurrent protection—The appliance is designed for an AC line voltage 
source with up to 20 amperes of overcurrent protection. If the power system for 
the equipment rack is installed on a branch circuit with more than 20 amperes of 
protection, you must provide supplemental protection for the appliance. If more 
than one appliance is installed in the rack, the power source for each appliance 
must be from a separate branch circuit.   
Temperature—The operating temperature of the appliance, when installed in an 
equipment rack, must not go below 5 °C (41°F) or rise above 35 °C (95 °F). 
Extreme fluctuations in temperature can cause a variety of appliance problems. 
Ventilation—The equipment rack must provide sufficient airflow to the front of 
the appliance to maintain proper cooling. There must be sufficient ventilation to 
exhaust at least 1,500 BTU per hour for each appliance. The rack selected and 
the ventilation provided must be suitable to the environment in which the 
appliance will be used.  
BIOS error codes 
The following is a list of BIOS error codes with their corresponding descriptions. 
BIOS error codes appear on the appliance's LCD screen. 
BIOS error code  Description 
0100h 
Timer Channel 2 Error 
0101h 
Master Interrupt Controller 
0102h 
Slave Interrupt Controller 
0103h 
CMOS Battery Failure 
0104h 
CMOS Options Not Set 
0105h 
CMOS Checksum Failure 
0106h 
CMOS Display Error 
0107h 
Insert Key Pressed 
0108h 
Keyboard Locked Message 
0109h 
Keyboard Stuck Key Message 
010Ah 
Keyboard Interface Error 
010Bh 
System Memory Size Error 
010Eh 
External Cache Failure 
0110h 
Floppy Controller Error