Smeg C30GGNU Instruction Manual

Page of 8
9
Conversion Kit
EN
6)
To adjust the range for LP gas or to return to Natural Gas use, refer to the charts below.
Natural gas
Qt
Injector
Qr
BTU
Ø mm
BTU
Front Right
Main
10100
1.39
4100
Simmer
0.56
1650
Center
Inner
17000
0,80
1100
Inner + Outer
1.80
5900
Front Left
Main
10100
1.39
4100
Simmer
0.56
1650
Rear Left
Main
10100
1.39
4100
Simmer
0.56
1650
Rear Right
Main
10100
1.39
4100
Simmer
0.56
1650
Oven
16500
2.05
4600
Broiler
12500
1.75
-
LP
Qt
Injector
Qr
By-pass
BTU
Ø mm
BTU
mm
Front Right
Main
10100
0.85
4100
99
Simmer
0.38
1950
44
Center
Inner
17000
0.46
1100
31
Inner + Outer
1.10
5900
65
Front Left
Main
10100
0.85
4100
99
Simmer
0.38
1950
44
Rear Left
Main
10100
0.85
4100
99
Simmer
0.38
1950
44
Rear Right
Main
10100
0.85
4100
99
Simmer
0.38
1950
44
Oven
16500
1.15
4600
68
Broiler
12500
1.00
-
-
NOTE: Save the nozzles that were removed from the appliance along with these instructions for possible
future use.
  WARNING
FIRE HAZARD
Use a soapy solution to check that it is leak-tight.
Never test for gas leaks with a match or other flames.
Failure to follow this instruction can result in loss of life or fire