Smeg C30GGNU Instruction Manual

Page of 8
10
Conversion Kit
EN
7)
Follow these instructions to leak test the appliance:
Use a brush and liquid detergent to test all gas connections for leaks. Bubbles around connections
indicate a leak. If a leak appears, shut off the gas valve controls and adjust the connections. Then check
the connections again. Remove all the detergent product from the range. Replace the parts on the
burner and turn the knobs on the gas tap pins.
NEVER TEST FOR GAS LEAKS WITH A MATCH OR OTHER FLAMES.
8)
Check that the flame at the maximum flame position has a blue color. It should be clean and soft in
character. No blowing or lifting of flame should occur. Occasional orange flashes are normal and reflect
different elements in the air or gas.
9)
Minimum adjustment for Natural Gas
Cooking Hob: Light the burner and turn the knob to the minimum
position 
. Remove the gas tap knob and turn the adjustment screw
at the side of the tap rod until the desired minimum flame is achieved.
Refit the knob and verify that the burner flame is stable (when turning
the knob rapidly from the maximum to the minimum position the flame
must not go out).
Repeat this operation on the remaining gas taps on the hob.
Oven: Light the burner and turn it to the maximum temperature for at
least 10 minutes. Then, turn the knob to the minimum position (LOW).
Remove the knob and, using a screwdriver, locate the adjustment
screw alongside of the tap rod (as shown in the figure).  Turn the
adjustment screw until the desired minimum flame is achieved.
Refit the knob and verify that the burner flame is stable (when turning
the knob rapidly from the maximum to the minimum position the flame
must not go out).
Moreover, check that the flame does not go out when the door is being
openend or closed.
10)
Minimum adjustment for LP Gas
Turn off the burners and unplug the appliance from the electrical power supply.
For regulating the minimum with LP, the screws at the side of the tap rod must be turned clockwise all the
way. Once the regulation has been completed, replace the seal on the by-passes using paint or similar
materials. Follow the instructions given in point 9 to locate the adjustment screws.
11)
Completely fill out the conversion label (part no. 92849A078) and attach it to the rear of the appliance.
Do not cover any other labels with the conversion label.
12)
At higher altitudes, no further adjustments are necessary. Derating the burners is also unnecessary.
NATURAL GAS:
To convert back to Natural Gas: Follow steps 1 through 9 and replace the nozzles in the order in which
they were removed.