Vinotemp VINOSONOMA250 Manual

Page of 17
                                                                                
13
Troubleshooting 
 
 
Troubleshooting Chart 
Complaint Possible 
Causes 
Response 
1. Unit not running 
 
a.  Power cord unplugged 
b.  No power to unit 
c. Temperature 
setting 
high 
d.  DOWN button lighting 
e.  UP button lighting 
a.  Check for power cord plug 
b.  Check for power at receptacle and fuses 
c. Lower 
temperature 
setting 
d. Under 
defrost 
e. Call 
service 
 
2. Temperature too high or unit running too long 
 
a.  Surrounding temperature high 
b. 
Improper evaporator or 
condenser air flow. 
c. Dirty 
Condenser 
d. Iced 
evaporator 
e. Improper 
seals 
f. 
Improper area to be cooled 
 
g. Refrigerant 
leakage 
h. Low 
voltage 
i. 
Operating 60 Hz unit at 50Hz 
 
a. Lower 
temperature 
setting 
b.  Check for air passage restrictions or 
obstruction; Check for fans .  
c.  Clean dirty condenser 
d.  Defrost and reset temperature control 
e.  Check for gasket and doors opening. 
f.  Check for excessive load or incorrect 
installation. 
g. Call 
for 
service 
h.  Check power supply 
i. 
The unit should be operating at 60 Hz 
3. Compressor stopping and starting, but short running time.
 
 
a. Incorrect 
voltage 
b. Improper 
condenser 
airflow 
 
c. Dirty 
condenser 
d. Failed 
components 
 
a.  Check for voltage 
b.  Check for wrong motors, fan blades, 
binding and bearings. 
c. Clean 
condenser 
d. Call 
service 
 
4. Excessive moisture on glass
 
 
a. Surrounding 
humidity 
high 
b. Improper 
seals 
c.  Often door opening  
a. Raise 
temperature 
setting 
b.  Check for gasket and doors opening 
c.  Reduce door opening duration  
5. House circuit tripping 
 
a.  Incorrect fuse or breaker. 
b.  Failed components or incorrect 
wirings 
 
a.  Check for proper fuse or breaker 
b.  Check wirings and connections  
 
6. Noisy operation 
 
a.  Mounting area not firm 
b.  Compressor overloaded due to 
high ambient temperatures, or 
airflow restriction. 
 
a.  Add support to improve installation. 
b.  Internal loose, inadequate lubrication, 
improper voltage, airflow blockage.