GE GTV21GSSJWW Specification Sheet

Page of 3
Dimensions and Installation Information (in inches) 
For answers to your Monogram,
® 
GE Profile
 or  
GE
®
 appliance questions, visit our website at 
geappliances.com or call GE Answer Center
®
 
service, 800.626.2000.
Specification Created 8/14
GTV21GSSJ 
GE
® 
7.0 cu. ft. capacity Dura Drum gas dryer with 150 ft. long venting
Exhaust Options: 
2-way via rear and bottom. Dryer is shipped exhausted to the rear. Alternate 
exhausting knockouts are supplied. 
Gas: An individual properly-grounded branch circuit, with a three-prong grounding-
type receptacle, protected by a 15 or 20 amp circuit breaker or a time-delay fuse  
is required.
Gas Dryer Electric Rating: 120V, 60Hz, 6A
Gas (BTU/HR): 22,000. Factory-equipped for natural gas. Tested for LP gas. LP gas 
supply requires a conversion kit. Check installation instructions for correct kit and 
have a qualified gas technician install a conversion kit. See dryer ducting information 
for proper installation.
Note: Dryer wall outlet must be located within 36" of service cord entry and 
accessible when dryer is mounted in position.
Installation Information: For complete information, see installation instructions 
packed with your dryer.
Special Installation Requirements
Alcove or Closet Installation:
 
•  If your dryer is approved for installation in an alcove or closet, it will be stated on a label 
on the dryer back.
• The dryer MUST be exhausted to the outside. 
•  Minimum clearances between dryer cabinet and adjacent walls or other surfaces 
are:
 
0" either side 
 
3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52". 
•  Closet doors must be louvered or otherwise ventilated and must contain a minimum 
of 60 sq. in. of open area equally distributed. If this closet contains both a washer and 
a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors. 
•  The installation must conform with the local codes, or in the absence of local codes, 
with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
Minimum Clearances other than Alcove or Closet Installation:
•  Minimum clearances to combustible surfaces 
  0" both sides 
  3" rear