GE GTV21GSSJWW Installation Instruction

Page of 8
WARNING 
RISK OF FIRE
•  To reduce the risk of severe injury or death, follow all installation 
instructions.
‡&ORWKHVGU\HULQVWDOODWLRQPXVWEHSHUIRUPHGE\DTXDOL¿HGLQVWDOOHU
•  Install the clothes dryer according to these instructions and in 
accordance with local codes.
•  California Safe Drinking Water and Toxic Enforcement Act
    This act requires the governor of California to publish a list of 
substances known to the state to cause cancer, birth defects or other 
reproductive harm and requires businesses to warn customers of 
potential exposure to such substances. Gas appliances can cause 
minor exposure to four of these substances, namely benzene, 
carbon monoxide, formaldehyde and soot, caused primarily by the 
incomplete combustion of natural gas or LP fuels. Properly adjusted 
dryers will minimize incomplete combustion. Exposure to these 
substances can be minimized further by properly venting the dryer 
to the outdoors.
•  This dryer must be exhausted to the outdoors.
•  Use only rigid metal 4” diameter ductwork inside the dryer cabinet 
and use only UL approved transition ducting between the dryer and 
the home duct.
‡'2127LQVWDOODFORWKHVGU\HUZLWKÀH[LEOHSODVWLFGXFWLQJ
PDWHULDOV,IÀH[LEOHPHWDO VHPLULJLGRUIRLOW\SH GXFWLVLQVWDOOHGLW
must be UL listed and installed in accordance with the instructions 
found in “Connecting The Dryer To House Vent” on page 5 of this 
manual. Flexible venting materials are known to collapse, be easily 
FUXVKHGDQGWUDSOLQW7KHVHFRQGLWLRQVZLOOREVWUXFWGU\HUDLUÀRZ
DQGLQFUHDVHWKHULVNRI¿UH
•  Do not install or store this appliance in any location where it could 
be exposed to water and or weather.
•  6DYHWKHVHLQVWUXFWLRQV ,QVWDOOHUV%HVXUHWROHDYHWKHVH
LQVWUXFWLRQVZLWKWKHFXVWRPHU 
IN THE COMMONWEALTH OF MASSACHUSETTS
•  This product must be installed by a licensed 
SOXPEHURUJDV¿WWHU
•  When using ball-type gas shut-off valves, 
WKH\VKDOOEHWKH7KDQGOHW\SH
•  A flexible gas connector, when used, must 
QRWH[FHHGIHHW
Installation
Instructions
Gas Dryer
03
BEFORE YOU BEGIN
Read these instructions completely and 
FDUHIXOO\
• 
IMPORTANT-
 Save these instructions for 
local inspector’s use.
• 
IMPORTANT-
 Observe all governing codes 
and ordinances.
 Note to Installer - %H VXUH WR OHDYH WKHVH
instructions with the customer.
•  Note to Customer - Keep these instructions with 
your Owner’s Manual for future reference.
‡ %HIRUHWKHROGGU\HULVUHPRYHGIURPVHUYLFHRU
discarded, remove the dryer door.
• Inspect the dryer exhaust outlet and straighten 
the outlet walls if they are bent.
•  Service information and the wiring diagram are 
located in the control console.
•  Do not allow children on or in the appliance. Close 
supervision of children is necessary when the 
appliance is used near children.
•  Install the dryer where the  temperature is above 
50°F for satisfactory operation of the dryer 
control system.
•  Product failure due to improper installation is not 
covered under the Warranty.
234D2217P003     31-16737    10-13  GE
LEVEL
8" PIPE WRENCH
10" ADJUSTABLE WRENCHES
 (x2)
TOOLS YOU WILL NEED
SLIP JOINT PLIERS
FLAT BLADE SCREWDRIVER
 
MATERIALS YOU WILL NEED
GLOVES
SAFETY
GLASSES
4" DUCT
CLAMPS (2)
OR
4" SPRING
CLAMPS (2)
EXHAUST
HOOD
4" DIA. METAL
ELBOW
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
 KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT
(IF NEEDED.)
DUCT TAPE
SOAP SOLUTION
FOR LEAK DETECTION
PIPE
COMPOUND
FLEXIBLE GAS LINE CONNECTOR
4XHVWLRQV"&DOO*(&$5(6  RUYLVLWRXU:HEVLWHDW*($SSOLDQFHVFRP 
,Q&DQDGDFDOORUYLVLWZZZ*($SSOLDQFHVFD