Marvel ML24BNS1RB Owner's Manual

Page of 32
14
!
CAUTION
!
WARNING
If you purchased an overlay panel model, your unit is 
equipped with articulated hinges to allow fully integrated 
built-in installations. Custom panel thicknesses of 
5
8
" (15 
mm) and 
3
4
" (18 mm) are accommodated.
Step 1: Removing the Door
With a phillips screwdriver remove the screw and "P" clamp 
from the bottom of the door near the hinge. See Figure 13b.
Disconnect the door wire harness by pressing and holding 
down the locking tab on the wire connector and pulling the 
connector apart. See Figure 14.
Open the door and loosen the screws holding the hinges to 
the cabinet (2 at the top and 2 at the bottom hinge). Do not 
remove the screws but loosen them enough so the hinges 
can be slipped off of the screws when sliding the door to 
the side.
With a helper, and being careful not to scratch the cabinet 
or the door, slide the door to the side about 
1
2
 inch and 
remove the hinges and door from the unit.
!
WARNING
Use extreme caution with the articulated hinges. The 
hinge is self closing and many pinch points exist prior 
to built-in installation. 
Do not remove the cabinet "Z" 
bracket from the top of the cabinet.
It is important to use the factory provided grille that came 
with the product to assure proper air flow is maintained 
through the condenser. The use of a custom grille is not 
recommended and will void the warranty.
Overlay panel models are designed for use with 
built-
in installations only. Use in freestanding installations 
could result in personal injury.
Figure 13b
Bottom of
door
Wire connector
see Figure 14
!
WARNING
The articulated hinges have many pinch points. Care-
fully close / collapse the hinges as soon as the door is 
removed from the cabinet.
OVERLAY DOOR PANEL INSTALLATION
Figure 13a
Loosen (do not remove) 
these 2 phillips head 
screws on the top and 
bottom hinges
"P" clamp 
and screw
Cabinet 
"Z" Bracket
Figure 13