Door Ajar
ALARM RESET
!
CAUTION
USING YOUR ELECTRONIC CONTROL
Temperature mode:
The temperature mode is preset from the factory in Fahren-
heit (°F) but you have the option to change it to Centigrade 
(°C). To change the mode, press and hold the "-" keypad, 
while pressing the "+" keypad, then release the "-" keypad.
The temperature will now be displayed in Centigrade (°C).
Repeat the procedure to change the temperature mode 
back to Fahrenheit (°F).
Control lock:
The control panel can be locked to avoid unintentional 
changes. To lock the control, press and hold the "Lock" key-
pad until the display reads "Loc" then release your finger 
from the keypad. The lock icon will flash 3-times and then 
continuously illuminate. When the control panel is locked, 
only the Lock keypad, System Status OK indicator , and 
the Alarm indicator are active. To un-lock the control panel, 
repeat this instruction until the display reads "nLc".
Alarms:
The control will alert you to conditions that could adversely 
affect the performance of the appliance.
•  Door ajar - 
If the door is open, or not closed prop-
erly, for more than 5-minutes the System Status OK 
indicator will turn-off, the "Door Ajar" indicator will flash, 
and a tone will sound every 60 seconds. Additionally, 
an "ALARM RESET" indicator will be displayed below 
the "On/Off" keypad. This alarm condition can be reset 
by closing the door or momentarily pressing the "On/
Off" keypad, (i.e.-if you are cleaning the storage com-
partment, etc.). The alarm will recur in 5-minutes if the 
alarm condition persists.
Adjusting the temperature:
To set or check the set-point temperature (with the control 
out of sleep mode), press the "-" or "+" keypads. "SET" will 
be indicated on the user interface panel and the current 
set-point temperature will display and flash. Subsequent 
presses of the "-" or "+" keypads will adjust the temperature 
colder or warmer respectively. When you have reached 
your desired set-point temperature, press the "On/Off" key-
pad to accept, or do nothing and the "Set" mode will time-
out in 10-seconds accepting the displayed temperature as 
the new set-point.
The available set-point temperature range for your ap-
pliance is 34°F (1.2°C) to 46°F (7.9°C). If you attempt to 
adjust the temperature outside of this range you will receive 
an audible notification.
If you are using the appliance as a refrigerator for perish-
able foods, the set-point temperature should be set be-
tween 34°F and 42° F (1.2° C and 5.7° C).
When initially loading your product with warm contents, it 
may take up to 48-hours for the storage compartment tem-
perature to stabilize.
When making temperature set-point changes, it may take 
up to 24-hours for the stored contents to stabilize at your 
new set-point temperature.
Factors that affect the storage compartment stabilized 
temperature:
•  Changes to temperature setting.
•  Room temperature changes.
•  Temperature of stored contents.
          - Loading warm contents.
          - Cold content load will delay the change to a warmer
            set-point temperature.
          - Warm content load will delay the change to a colder
            set-point temperature. 
•  Usage, (number and duration of the door openings).
•  Installation of the appliance in direct sunlight or next to 
a heat source.