 17
Installation Instructions
Snip all 4 webs  
on each knockout 
panel and remove  
the metal knockouts 
for rear airflow.
    Locate the two “knockout” plates, on the rear oven 
panel, near the top of the oven. 
    Using tin snips, carefully cut the web area from the 
two holes side-by-side (that secure the knockouts to 
the oven). Cut all four webs on both rear knockouts; 
this will allow the ventilation fan airflow to exhaust 
out the rear of the oven.
   
CAUTION:
 Be sure to trim the sharp 
edges from the openings after removing the 
knockout plates.
   AFTER:  Fan  Blade      
Openings Facing 
Back
7
    Place the blower unit back into the opening.  
9
    Insert the tabs on each side of the damper  
into the holes at the inside rear of the adaptor.
8
  Roll the blower unit 90° so that fan blade openings 
are facing out the back of the oven. 
5
Blower Plate
    Replace the blower plate in the same position 
as before with the screws.
Before Rolling
After Rolling
Back of Oven
End A
End B
Back of 
Oven
Back of 
Oven
   
WARNING:
 Risk of electric shock 
can cause injury or death.  Do not pull or stretch 
the blower unit wiring.  make sure the wires are 
not pinched..
   NOTE: The blower unit exhaust openings should 
match exhaust openings on rear of microwave oven.
Blower Plate Screws
Oven Rear Panel
6
    Attach the exhaust adaptor to the rear of the oven 
by sliding it into the guides at the top center of the 
back of the oven.
10
    Secure the exhaust adaptor to the oven with  
the two bronze metal screws provided.
11
    Push in securely until it is in the lower locking tabs. 
Take care to assure the damper hinge is installed 
so that it is at the top and that the damper swings 
freely.
Slide exhaust 
adaptor into 
guides on  
oven rear.
Exhaust Adaptor
Damper  
(hinge side up)
Locking  
Tabs
Guides
Back of Oven
Exhaust 
Adaptor
Screws