Lynx L700PS Use & Care Manual

Page of 40
24   
 
|
 
 
SEDONA CARE & USE/INSTALLATION
CUT-OUT DIMENSIONS FOR BUILT-IN GRILLS
Note: For Natural Gas grills, the manufacturer 
recommends using 3/4” gas supply lines.
COUNTERTOP NOTCH DETAIL
Only required if island countertop          
overhangs the face of the island
NOTE: Insulating jacket required for all 
grills installed into a combustible enclosure.
Note: Side burners may be rotated 90 degrees.
INSULATING JACKET
An enclosure for an LP-gas cylinder shall be ventilated by openings at 
both the upper and lower levels of the enclosure. The effectiveness of the 
opening(s) for purposes of ventilation shall be determined with the LP-gas 
supply cylinder in place. This shall be accompanied by one of the follow-
ing:
a)  One side of the enclosure shall be completely open; or
b)  For an enclosure having four sides, a top and a bottom:
1. At least two ventilation openings shall be provided in the side walls of the 
enclosure, located within 5 in (217 mm) of the top of the enclosure, equally 
sized, spaced at a minimum of 90 degrees (1.57 rad), and unobstructed. The 
opening(s) shall have a total free area of not less than 1 in 2/ lb (14.2 cm2/
kg) of stored fuel capacity.
2. Ventilation opening(s) shall be provided at floor level of the enclosure and 
shall have a total free area of not less than 1/2 in2/lb (7.1 cm2/kg) of stored 
fuel capacity. If ventilation openings at floor level are in a side wall, there 
shall be at least two openings. The bottom of the openings shall be 1 in 
(25.4 mm) or less from the floor level and the upper edge no more than 5 in 
(127 mm) above the floor level. The openings shall be equally sized, spaced 
at a minimum of 90 degrees (1.57 rad) and unobstructed.
3. Every opening shall have minimum dimensions so as to permit the entrance 
of a 1/8  in (3.2 mm) diameter rod.
4. Ventilation openings in side walls shall not communicate directly with other 
enclosures of the outdoor cooking gas appliance.
Keep the ventilation openings of the cylinder enclosure free and clear from 
debris.
A
4.5”
5”
3”
C
B
BUILT-IN GRILL
Model  
   A  
   B  
   C
L400 
23.00 10.00 21.25
L500  
29.00  
10.00 
21.25
L600 
35.00 10.00 21.25
L700 
41.00 10.00 25.25
COMPLEMENTARY PRODUCTS
Model  
   A  
   B  
   C
LSB501  
11.00 
4.00  
16.00
LSB502 
21.00  
4.00  
16.00
LDR424 
22.00 19.00 –
LDR530  
28.25 
19.00  
–  
LDR636 
33.75 19.00 –
LSA530  
28.25  
19.00  
20.00
LSA636    
33.75 
19.00 
20.00
LUD517  
17.25  
12.75  
20.00 
L500REF  
21.50  
34.00 
24.50
BUILT-IN GRILL W/ INSULATING JACKET
Model  
   A  
   B  
   C
LIJ400 
30.00 11.62 23.25
LIJ500  
36.00  
11.62  
23.25
LIJ600 
42.00 11.62 23.25
LIJ700 
48.00 11.62 23.25
A
A
0.56”
Double
Drawers
(LUD)
Single & 
Double Side 
Burner (LSB)
Outdoor
Refrigerator
(L500REF)
Door & Drawer Options
(LDR, LSA or LTA)
CUTOUT NOT
REQUIRED
WITH LIJs
Locate a 110 V 15Amp
GFI outlet for rotisserie  
models.
B
C
A
B
3.50”
3.50”
12.00”
2.00”
34.00”
2.25”
21.50”
A
When installing the LSB side burners  
  over the refrigerator, the counter top  
  must be at least 37-1/2” above the floor.