Whirlpool CGM2743BQ Installation Instruction

Page of 48
10
Your dryer can be installed in a basement, laundry room, or 
recessed area.
Companion appliance location requirements should also be 
considered.
IMPORTANT: Do not install or store the dryer where it 
will be exposed to the weather. Proper installation is your 
responsibility.
You will need:
 
A grounded electrical outlet located within 6 ft. (1.8 m) of 
where the power cord is attached to the back of the dryer. 
See “Electrical Requirements.”
 
A level floor with a maximum slope of 1" (25 mm) under 
entire dryer. Installing the dryer on soft floor surfaces, 
such as carpets or surfaces with foam backing, is not 
recommended.
Electric dryer installation clearances
 
The location must be large enough to allow the dryer door  
to be fully opened.
 
Additional spacing should be considered for ease of 
installation and servicing. The door opens more than 180°.
 
Additional clearances might be required for wall, door, and 
floor moldings.
 
Additional spacing of 1" (25 mm) on all sides of the dryer is 
recommended to reduce noise transfer.
Recessed Area and Closet Installation Instructions
This dryer may be installed in a recessed area or closet. For 
recessed area and closet installations, minimum clearances  
can be found on the warning label on the rear of the dryer  
or in “Dimensions/Clearances.”
The installation spacing is in inches and is the minimum 
allowable. Additional spacing should be considered for ease 
of installation, servicing, and compliance with local codes and 
ordinances.
If closet door is installed, the minimum unobstructed air 
opening in the top and bottom is required. Louvered doors  
with equivalent air openings are acceptable.
Location Requirements
The dryer must be exhausted outdoors.
24 in.
2
(155 cm
2
)
48 in.
2
(310 cm
2
)
3"
(76 mm)
3"
(76 mm)
Closet
door
Front
View
ELECTRIC DRYER INSTALLATION REQUIREMENTS
Closet 
Door
Front 
View
Electrical Requirements – U.S.A. only
It is your responsibility:
 
To contact a qualified electrical installer.
 
 To be sure that the electrical connection is adequate and in 
conformance with the National Electrical Code, ANSI/NFPA 
70-latest edition and all local codes and ordinances.
 
 The National Electrical Code requires a 4-wire power supply 
connection for homes built after 1996, dryer circuits involved 
in remodeling after 1996, and all mobile home installations.
 
 A copy of the above code standards can be obtained from: 
National Fire Protection Association, One Batterymarch 
Park, Quincy, MA 02269.
 
 To supply the required 3 or 4 wire, single phase, 120/240 
volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 
120/208 volt electrical supply, if specified on the serial/
rating plate) on a separate 30-amp circuit, fused on both 
sides of the line. A time delay fuse or circuit breaker is 
recommended. Connect to an individual branch circuit.  
Do not have a fuse in the neutral or grounding circuit.
 
Do not use an extension cord.
 
 If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrician determine that the 
ground path is adequate.