Whirlpool WOC54EC7A Quick Setup Guide

Page of 16
5
INSTALLATION INSTRUCTIONS
Prepare Built-In Microwave/Oven 
Combination
1. Decide on the final location for the oven. Locate existing 
wiring to avoid drilling into or severing wiring during 
installation. 
2. To avoid floor damage, set the oven onto cardboard prior to 
installation. Do not use handle or any portion of the front 
frame for lifting.
3. Remove the shipping materials and tape from the oven.
4. Remove the hardware package from inside the bag 
containing literature.
5. Remove and set aside racks and other parts from inside the 
oven.
6. Move oven and cardboard close to the oven’s final location.
Remove Oven Door
IMPORTANT: Use both hands to remove oven door(s).
1. Open the oven door.
2. Locate the oven door latches in both corners of the oven 
door, and rotate the latches forward to the unlocked position.
3. Grasp the edges of the oven door with both hands and close 
the oven door until it will no longer close. Lift and pull oven 
door toward you and remove. Set the oven door aside on a 
covered work surface. 
Make Electrical Connection
IMPORTANT: For model KEHU309B, you must use 6 gauge 
copper or 4 gauge aluminum wire. 
This oven is manufactured with a neutral (white) power supply 
wire and a cabinet-connected green (or bare) ground wire twisted 
together.
1. Disconnect power.
2. Feed the flexible conduit from the oven through the opening 
in the cabinet. 
3. Remove junction box cover, if it is present.
4. Install a UL listed or CSA approved conduit connector to the 
junction box.
5. Route the flexible conduit from the oven to the junction box 
through a UL listed or CSA approved conduit connector.
6. Tighten screws on conduit connector.
7. See “Electrical Connection Options Chart” to complete 
installation for your type of electrical connection.
A. Oven door latch in locked 
position
B. Oven door latch in unlocked 
position
WARNING
Excessive Weight Hazard
Use two or more people to move and install oven.
Failure to do so can result in back or other injury.
A
B
A. UL listed or CSA approved conduit connector
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge solid copper wire.
Electrically ground oven.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 6 gauge copper or 4 gauge aluminum wire.
Electrically ground oven.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
A