Thermador PH48GS Installation Instruction

Page of 50
English 13
Wiring the Hood with a 
Remote Blower
Both Pro 24" Wall Hood and Pro 27" Wall Hood models can 
be installed with remote blowers (Figure 20). For 
installation instructions see the instructions supplied with 
the blower unit.
1.
Remove the junction box cover.
2.
Install 1/2” (13mm) conduit connectors.
3.
Run black, white, and green wires (#12 AWG) in 1/2” 
(13mm) conduit from power supply to junction box.
4.
Connect the power supply wires to the hood wires in 
the following order: black to black, white to white, and 
green wire to green ground screw on chassis. Use 
spring type wire nuts supplied. (Lost or missing wire 
nuts should only be replaced with: Spring type wire 
nuts, rated for a minimum of (2) # 18ga wires and 
maximum of (4) #14ga wires, UL & CSA rated to 600V 
and 302° F/ 150° C).
5.
Connect the “pigtail” to the connector inside the 
junction box.
6.
Run (5) wires (#14 AWG) in 1/2” (13mm) conduit from 
the remote blower to the second conduit connector. 
7.
Connect the remote blower to the pigtail wires (Step 6) 
as per Figure 21. Connect the remote blower green 
(ground) wire to the ground screw in the junction box. 
Refer to the blower installation instructions for further 
wiring details. 
8.
Close junction box cover. Check that all light bulbs are 
secure in their sockets. Install filters (“Installing Filters, 
Grease Trays, and Heat Lamps” on page 15). Turn 
power on at service panel, and check lights and blower 
operation per Use & Care Manual.
 Figure 20: Remote Blower
 Figure 21: Wiring the Hood with a Remote Blower
13 
5
/
8
(346mm)
1
/
8
12 
1
/
8
(308mm
)
(54mm)
1
/
8
(54mm)
19
 
7
/
8
(505mm)
(349mm)
13
 3
/
4
10”
(254mm)
1
/
2
(165mm)
1
7
/
8
(48mm)
12 
7
/
8
(327mm)
9
7
/
8
(251mm)