Gaggenau AL400721 Brochure
156
Cooktops
C G 290 111F
Glass ceramic
Width 90 cm
Liquid gas 28 – 37 mbar
Width 90 cm
Liquid gas 28 – 37 mbar
C G 290 211
Glass ceramic
Width 90 cm
Natural gas 20 mbar
Nozzles for liquid gas 50 mbar included
Width 90 cm
Natural gas 20 mbar
Nozzles for liquid gas 50 mbar included
Special accessories
W P 400 001
W P 400 001
Wok pan made of multiple-layer
material
With round bottom and handle,
ø 36 cm, 6 litres, height 10 cm.
material
With round bottom and handle,
ø 36 cm, 6 litres, height 10 cm.
Gas cooktop
C G 290
– For flush or conventional
installation
– Two-ring burner with 6,000 W
Cooking zones
1 wok burner with 2 separately
adjustable flame rings (300 W -
6,000 W), suitable for pots up to max.
ø 32 cm.
1 high output burner (590 – 2,800 W),
suitable for pots up to max. ø 26 cm.
2 standard burners (370 – 1,900 W),
suitable for pots up to max. ø 20 cm.
1 economy burner (310 – 1,100 W),
suitable for pots up to max. ø 14 cm.
adjustable flame rings (300 W -
6,000 W), suitable for pots up to max.
ø 32 cm.
1 high output burner (590 – 2,800 W),
suitable for pots up to max. ø 26 cm.
2 standard burners (370 – 1,900 W),
suitable for pots up to max. ø 20 cm.
1 economy burner (310 – 1,100 W),
suitable for pots up to max. ø 14 cm.
Handling
Control knobs with cooking zone and
output level markings.
One-handed operation.
Electric ignition.
output level markings.
One-handed operation.
Electric ignition.
Features
Three-part cast pan support with
continuous pot surface.
Enamelled burner cover.
continuous pot surface.
Enamelled burner cover.
Safety
Thermoelectric safety pilot.
Planning notes
The cooktop can be conventionally
built into worktops or flush integrated
into stone worktops.
Special nozzles can be ordered as
spare parts.
Installation in a 85 cm niche or a
88 cm niche with the included
spacers.
Air intake from above.
Intermediate shelf is required.
Appliance must be fixed from
underneath.
A minimum clearance of at least
150 mm from adjacent heat-sensitive
furniture or contact surfaces must be
observed or thermal insulation fitted.
Cooktop clamping range: 30 – 50 mm.
With a total connected load of more
than 12 kW local regulations
concerning room ventilation, room size
and combination of extraction or
recirculation hoods must be observed.
Minimum clearance between gas
cooktop(s) with more than 12 kW and
ventilation hood 70 cm.
Appliance weight: approx. 20 kg.
built into worktops or flush integrated
into stone worktops.
Special nozzles can be ordered as
spare parts.
Installation in a 85 cm niche or a
88 cm niche with the included
spacers.
Air intake from above.
Intermediate shelf is required.
Appliance must be fixed from
underneath.
A minimum clearance of at least
150 mm from adjacent heat-sensitive
furniture or contact surfaces must be
observed or thermal insulation fitted.
Cooktop clamping range: 30 – 50 mm.
With a total connected load of more
than 12 kW local regulations
concerning room ventilation, room size
and combination of extraction or
recirculation hoods must be observed.
Minimum clearance between gas
cooktop(s) with more than 12 kW and
ventilation hood 70 cm.
Appliance weight: approx. 20 kg.
Connection
Total connected load gas
13.7/13.7 kW .
Connecting cable 1.0 m without plug.
13.7/13.7 kW .
Connecting cable 1.0 m without plug.