156
Cooktops
    
   C   G 290 111F
 
   Glass  ceramic
  Width  90  cm
  Liquid  gas  28 – 37 mbar
     C   G 290 211
 
   Glass  ceramic
  Width  90  cm
  Natural  gas  20  mbar
  Nozzles for liquid gas 50 mbar included
            Special  accessories
    W   P 400 001
 
  Wok pan made of multiple-layer 
material
   With round bottom and handle, 
ø 36 cm,  6 litres,  height  10 cm.
         Gas  cooktop
  C   G 290 
 
–    For  flush  or  conventional 
installation
 
–   Two-ring burner with 6,000 W
     Cooking  zones
  1 wok burner with 2 separately 
adjustable flame rings (300 W - 
6,000 W), suitable for pots up to max. 
ø 32 cm.
  1 high output burner (590 – 2,800 W), 
suitable for pots up to max. ø 26 cm.
  2 standard burners (370 – 1,900 W), 
suitable for pots up to max. ø 20 cm.
  1 economy burner (310 – 1,100 W), 
suitable for pots up to max. ø 14 cm.
    Handling
  Control knobs with cooking zone and 
output level markings.
  One-handed  operation.
  Electric  ignition.
    Features
  Three-part cast pan support with 
continuous pot surface.
  Enamelled  burner  cover.
    Safety
  Thermoelectric  safety  pilot.
    Planning  notes
  The cooktop can be conventionally 
built into worktops or flush integrated 
into stone worktops.
  Special nozzles can be ordered as 
spare parts.
  Installation in a 85 cm niche or a
88 cm niche with the included
spacers.
  Air intake from above.
  Intermediate shelf is required.
  Appliance must be fixed from 
underneath.
  A minimum clearance of at least 
150 mm from adjacent heat-sensitive 
furniture or contact surfaces must be 
observed or thermal insulation fitted.
  Cooktop clamping range: 30 – 50 mm.
  With a total connected load of more 
than 12 kW local regulations 
concerning room ventilation, room size 
and combination of extraction or 
recirculation hoods must be observed. 
Minimum clearance between gas 
cooktop(s) with more than 12 kW and 
ventilation hood 70 cm.
  Appliance weight: approx. 20 kg.
    Connection
  Total connected load gas 
 13.7/13.7   kW .
  Connecting cable 1.0 m without plug.