Gaggenau AL400721 Brochure
204
Ventilation appliances
V L 414 110
Stainless steel
Ventilation element
Air extraction/recirculation with remote
fan unit AR 400/401/403/413
Without motor and control knob
Ventilation element
Air extraction/recirculation with remote
fan unit AR 400/401/403/413
Without motor and control knob
Necessary installation accessories
A A 490 110
A A 490 110
Vario control knob ventilation 400
series
Stainless steel
For operation of one remote fan unit
AR 400/401/403/413
In combination with up to four
ventilation elements VL 414 connected
to one remote fan unit
Solid stainless steel control knob
Can be combined perfectly with other
Vario appliances of the 400 series
series
Stainless steel
For operation of one remote fan unit
AR 400/401/403/413
In combination with up to four
ventilation elements VL 414 connected
to one remote fan unit
Solid stainless steel control knob
Can be combined perfectly with other
Vario appliances of the 400 series
Installation accessories
A D 724 040
A D 724 040
Connection piece for cylindrical duct
DN 125
DN 125
A D 724 041
Connection piece for cylindrical duct
DN 125
Necessary for installation to left or
right side of VL 414.
DN 125
Necessary for installation to left or
right side of VL 414.
A D 854 046
Flat duct system with conducting fins
Connection piece VL 414 for DN 150
flat rectangular
Connection piece VL 414 for DN 150
flat rectangular
A S 070 000
Connection piece for extension in the
case of installation next to VK or VF
case of installation next to VK or VF
V A 420 000
Connection strip for combination with
other Vario appliances of the 400
series for flush installation
other Vario appliances of the 400
series for flush installation
V A 420 001
Connection strip for combination with
other Vario appliances of the 400
series for flush installation with
appliance cover/adjustment strip
other Vario appliances of the 400
series for flush installation with
appliance cover/adjustment strip
V A 420 010
Connection strip for combination with
other Vario appliances of the 400
series for surface installation
other Vario appliances of the 400
series for surface installation
V A 420 011
Connection strip for combination with
other Vario appliances of the 400
series for surface installation with
appliance cover/adjustment strip
other Vario appliances of the 400
series for surface installation with
appliance cover/adjustment strip
V A 450 110
Stainless steel adjustment strip 11 cm
Required accessory for combination of
several Vario appliances of the 400
series with at least one appliance cover
to compensate the appliance depth.
Required accessory for combination of
several Vario appliances of the 400
series with at least one appliance cover
to compensate the appliance depth.
Special accessories
A A 414 010
A A 414 010
Air baffle for combination with gas
cooktops
cooktops
Installation accessories for the air
recirculation ducts you will find at the
pages 236–239 .
recirculation ducts you will find at the
pages 236–239 .
Vario downdraft ventilation 400 series
V L 414
– Highly efficient ventilation system at
the cooktop
– Up to 4 ventilation elements can be
connected to one remote fan unit,
operated using one control knob
AA 490
operated using one control knob
AA 490
– Flexible power distribution, precise
extraction of cooking vapours only
at the open ventilation elements
at the open ventilation elements
– Precision crafting of 3 mm stainless
steel
– For surface installation with a
visible edge or for flush installation
– Can be combined perfectly with
other Vario appliances of the 400
series
series
– Compact ducting in connection
with flat rectangular pipes AD 8..
– Minimal planning and easy
installation for air recirculation
Output
Maximum air output in combination
with remote fan units s. table remote
fan units on page 252/253.
Sound power level depends on the
built-in situation.
with remote fan units s. table remote
fan units on page 252/253.
Sound power level depends on the
built-in situation.
Features
Manual opening of the ventilation
element.
Closing element made of stainless
steel, dishwasher-safe.
Metal grease filter with grease drip
tray, dishwasher-safe.
Sensor-controlled operation of the
extractor fan if at least one ventilation
element VL 414 is open.
No duct connection piece included.
element.
Closing element made of stainless
steel, dishwasher-safe.
Metal grease filter with grease drip
tray, dishwasher-safe.
Sensor-controlled operation of the
extractor fan if at least one ventilation
element VL 414 is open.
No duct connection piece included.
Planning notes
Depending on the type of installation
(surface-mounted or flush-mounted,
with or without an appliance cover), the
specific location of the cut-out and the
knob positions may vary.
If installing with the appliance cover
VA 440 or adjustement strip VA 450
take into account the additional space
required for the depth.
If combining several appliances with at
least one appliance cover, the
adjustment strip VA 450 is required to
compensate for the depth of the
appliance without the appliance cover.
If combining several Vario appliances
of the 400 series, a connection strip
VA 420 must be placed between the
appliances. Depending on the type of
installation, the corresponding
connection strip must be provided.
In the cut-out, the installation system
requires the side edge to be at least
10 mm for surface installation and at
least 13 mm for flush installation.
Ensure a continuous cut surface of
90°.
The bearing capacity and stability, in
the case of thin worktops in particular,
must be supported using suitable
substructures. Take into account the
appliance weight and additional loads.
Additional instructions for flush installa-
tion:
Installation is possible in worktops
made of stone, synthetics or solid
wood. Heat resistance and watertight
sealing of the cut edges must be
observed. Concerning other materials
please consult the worktop manu-
facturer.
The groove must be continuous and
even, so that uniform placing of the
appliance on the gasket is ensured.
(surface-mounted or flush-mounted,
with or without an appliance cover), the
specific location of the cut-out and the
knob positions may vary.
If installing with the appliance cover
VA 440 or adjustement strip VA 450
take into account the additional space
required for the depth.
If combining several appliances with at
least one appliance cover, the
adjustment strip VA 450 is required to
compensate for the depth of the
appliance without the appliance cover.
If combining several Vario appliances
of the 400 series, a connection strip
VA 420 must be placed between the
appliances. Depending on the type of
installation, the corresponding
connection strip must be provided.
In the cut-out, the installation system
requires the side edge to be at least
10 mm for surface installation and at
least 13 mm for flush installation.
Ensure a continuous cut surface of
90°.
The bearing capacity and stability, in
the case of thin worktops in particular,
must be supported using suitable
substructures. Take into account the
appliance weight and additional loads.
Additional instructions for flush installa-
tion:
Installation is possible in worktops
made of stone, synthetics or solid
wood. Heat resistance and watertight
sealing of the cut edges must be
observed. Concerning other materials
please consult the worktop manu-
facturer.
The groove must be continuous and
even, so that uniform placing of the
appliance on the gasket is ensured.
Do not use discontinuous lining.
The joint width may vary due to size
tolerances of the combinations and of
the worktop cut-out.
If installing several appliances in
individual cut-outs allow for a division
bar of minimum 50 mm between the
individual cut-outs.
The joint width may vary due to size
tolerances of the combinations and of
the worktop cut-out.
If installing several appliances in
individual cut-outs allow for a division
bar of minimum 50 mm between the
individual cut-outs.
Please read additional planning notes
on page 116–123 .
on page 116–123 .
Air extraction operation in combination
with remote fan units AR 400/401/403
or recirculation mode with AR 413.
Please refer to page 228–233 for
recommended configurations of
downdraft ventilations and remote fan
units and the needed ducting
elements.
Maximum cooktop width between two
VL: 60 cm.
If operated next to gas appliances, the
air baffle AA 414 010 is recommended
to ensure maximum performance of the
cooktop.
If installed next to gas appliances, flat
ducts must not be used for the piping
up to the fan unit.
If installed next to VP 414, the flat duct
must not be positioned underneath the
VP 414.
For maximum duct lengths use
Gaggenau flat rectangular ducts AD 8…
or Naber-System Compair flow. Other
flat ducts are not permitted!
Pipe connection pieces must be
ordered separately as installation
accessories. Connection NW 125
round on the bottom with AD 724 040,
on the sides with AD 724 040 and
AD 724 041.
Connection NW 150 flat ducting on the
side with AD 854 042.
Connection of 2 VL with ducting
2x DN 125 cylindrical or 2x DN 150
rectangular at remote fan AR 4.. .
For leading through the floor DN 150
cylindrical with connection of 2 DN 125
cylindrical use Y-joint AD 754 044.
Direct connection of 3 or 4 VL 414 only
on one AR 400 140, without
air-collector or Y-joint.
Please ensure when installing the
exhaust air ducting that no sharp
bends are caused and that the
cross-section of the ducting is not
constricted in any way.
For downdraft configurations with
maximum lengths of exhaust air ducts
go to Rodun at www.gaggenau.com.
Appliance can be snapped into the
worktop from above. Additional fixing
by clamps accessible from above,
clamping range 30-50 mm.
Appliance weight: approx. 3 kg.
with remote fan units AR 400/401/403
or recirculation mode with AR 413.
Please refer to page 228–233 for
recommended configurations of
downdraft ventilations and remote fan
units and the needed ducting
elements.
Maximum cooktop width between two
VL: 60 cm.
If operated next to gas appliances, the
air baffle AA 414 010 is recommended
to ensure maximum performance of the
cooktop.
If installed next to gas appliances, flat
ducts must not be used for the piping
up to the fan unit.
If installed next to VP 414, the flat duct
must not be positioned underneath the
VP 414.
For maximum duct lengths use
Gaggenau flat rectangular ducts AD 8…
or Naber-System Compair flow. Other
flat ducts are not permitted!
Pipe connection pieces must be
ordered separately as installation
accessories. Connection NW 125
round on the bottom with AD 724 040,
on the sides with AD 724 040 and
AD 724 041.
Connection NW 150 flat ducting on the
side with AD 854 042.
Connection of 2 VL with ducting
2x DN 125 cylindrical or 2x DN 150
rectangular at remote fan AR 4.. .
For leading through the floor DN 150
cylindrical with connection of 2 DN 125
cylindrical use Y-joint AD 754 044.
Direct connection of 3 or 4 VL 414 only
on one AR 400 140, without
air-collector or Y-joint.
Please ensure when installing the
exhaust air ducting that no sharp
bends are caused and that the
cross-section of the ducting is not
constricted in any way.
For downdraft configurations with
maximum lengths of exhaust air ducts
go to Rodun at www.gaggenau.com.
Appliance can be snapped into the
worktop from above. Additional fixing
by clamps accessible from above,
clamping range 30-50 mm.
Appliance weight: approx. 3 kg.
Connection
Connection cable 2.0 m between
ventilation element VL 414 and control
knob AA 490.
ventilation element VL 414 and control
knob AA 490.