Lynx LPZAF Owner's Manual

Page of 36
NAPOLI PIZZA OVENS CARE & USE/INSTALLATION
  
|
21
WARNINGS
WARNING
STATE OF MASSACHUSETTS
1.  Massachusetts requires all gas be installed using a plumber or gas fitter carrying the appropriate 
Massachusetts license.
2.  All permanently-installed natural gas or propane installations require a “T” handle type manual gas valve be 
installed in the gas supply line to this appliance.
3.  This does not apply to portable propane installations using a 20 pound cylinder.
1.  The outdoor cooking gas appliance and its individual shutoff valve must be disconnected from the gas supply 
piping system during any pressure testing of that system at test pressures in excess of 0.5 psi (3.5 kPa).
2.  The outdoor cooking gas appliance must be isolated from the gas supply piping system by closing its 
individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures 
equal to or less than 1/2 psi (3.5 kPa).
WARNING
1.  Always maintain the required clearances from combustible construction as detailed. The oven is designed for 
outdoor use only. Never use in a garage, building, shed, breezeway or other enclosed area. This oven shall 
not be used under any unprotected overhead combustible construction. 
2.  Gas ovens are not design certified for and are not to be installed in or on recreational vehicles, portable 
trailers, boats or any other moving installation. 
3.  Keep any electrical supply cord and the fuel supply hose away from any heated surfaces. Electrical cords 
should be placed away from walkways to avoid creating a tripping hazard. 
4.  Do not repair or replace any part of the oven unless specifically recommended in this manual. Other service 
should be performed by a qualified technician. 
5.  All gas lines must have a shut-off that is readily and easily accessible. Be sure the owner knows where the 
shut-off is located. If you smell gas, check for gas leaks immediately. Check only with a soap and water 
solution. Never check for gas leaks with an open flame. (See INDEX: “Leak Testing” for further details.)