Lynx LPZAF Owner's Manual

Page of 36
30   
 
|
 
 
NAPOLI PIZZA OVENS CARE & USE/INSTALLATION
FINAL CHECKS
LEAK TESTING
Leak Test Procedure:
• Create a soapy solution of 1 part soap and 3 parts water. 
• Confirm that all control knobs are in the off position. 
• Turn on the fuel supply. For natural gas, turn the valve 
handle 1/4 turn to align with the gas flow.  
• For L.P., turn the cylinder valve knob counter clockwise 
one full rotation. 
• Apply the soap solution generously by paint brush or 
squirt bottle on all connections and fittings. 
• If bubbles appear to “grow” on any of the 
connections, you have a gas leak. IMMEDIATELY turn 
off the gas supply. 
Fixing a Gas Leak:
• Shut off the gas supply
• Turn all oven controls to the “ON” position to purge the 
oven of any gas build-up, then turn the controls back 
“OFF”. 
• Wash off the soapy solution with cold water and dry. 
• Tighten the loose joint, or replace the faulty part with 
manufacturer-recommended replacement parts. 
• DO NOT attempt to repair the L.P. cylinder valve if it is 
damaged. The only way to safely resolve a damaged 
cylinder is to REPLACE IT. 
• Repeat the leak test to ensure that no leaks are present.
NOTE: The burners do not have an air shutter.
• The appearance of the burners should be visually 
checked. The ceramic tiles should be uniformly red to 
orange in appearance. Burners flames should be 4-5 
inches tall and predominately blue in color with some 
yellow tipping. There should be no lifting, fluttering or 
lazy blue flames. Some food particles will show as yellow 
flames but should burn off.
ONE LAST THING
Finally, before leaving, check all the burners for proper 
operation. Make sure the control knobs turn freely and 
completely through their full range.
IMPORTANT:
Make sure the owner knows where the main gas supply 
shut off valve is located.
Finally, for safety and for proper use & care, you must 
leave this manual with the owner. Make sure you advise 
them to keep it for future reference.
For technical assistance call:
Lynx Customer Care 
888-289-5969
To prevent fire or explosion hazard, DO NOT 
smoke or allow any potential source of ignition 
(sparks, electrical arcing, etc) in the area while 
performing a leak test. Leak tests should be 
conducted outdoors only. Never conduct a leak 
test using fire or flame.
DANGER!